不同形式温湿度独立控制空调系统在华南地区办公建筑节能潜力研究
[Abstract]:Many scholars have analyzed the energy saving potential of different temperature and humidity independent control air conditioning systems. However, many researchers ignore the following two problems when analyzing the potential of energy saving: first, the high temperature chiller can not realize the operation of high temperature effluent all year, so it is necessary to revise its comprehensive energy efficiency ratio. Second, the resistance of the fresh air unit and the dry end used to control the humidity is different from that of the conventional air conditioning system. The change of energy consumption caused by the change of the resistance of the fresh air unit and the dry end does not take into account the calculation of the comprehensive energy efficiency ratio. This leads to some deviation between the energy saving potential obtained by analysis and calculation and the practical energy saving potential in theory. Taking the office buildings in South China as the research object, this paper focuses on the energy saving potential of four different types of temperature and humidity independent control air conditioners on the premise of correcting the above two problems. Specifically, the main research work can be divided into the following three parts. The first part is to analyze the operation principle of different temperature and humidity independent control air conditioning system in theory, and to analyze the difference of dehumidification principle of different temperature and humidity independent control air conditioning system. The dehumidification of high temperature cold source double temperature cold source fresh air unit and high temperature cold source solution fresh air unit is a suitable air conditioning system with independent control of temperature and humidity. The second part: firstly, the load handling strategy of the air conditioning system with different temperature and humidity independent control and the resistance change of the fresh air unit and the dry end equipment are studied, and then the annual actual operating energy efficiency ratio of the high temperature chiller is revised. The revised high-temperature chillers should reduce their overall energy efficiency by 3% a year. Finally, the annual energy consumption of different temperature and humidity independent control air conditioning system is calculated synthetically, and the energy saving potential of different temperature and humidity independent control air conditioning system is analyzed, and the high temperature cold source and pre cooling double temperature cold source fresh air unit are obtained. The energy saving rates of heat recovery type double temperature cold source fresh air unit, pre cooling solution dehumidifying fresh air unit and heat recovery solution dehumidifying fresh air unit are 20. 2 and 19. 1 respectively. The third part analyzes the selection of outdoor calculation parameters of air conditioning system with independent control of temperature and humidity. It is suggested that the calculation value of outdoor humidity should be selected according to the guarantee rate. The differences between the design and operation of temperature and humidity independent control air conditioning system and conventional air conditioning system are put forward, which can provide a reference for the design and operation of the actual temperature and humidity independent control air conditioning system engineering.
【学位授予单位】:华南理工大学
【学位级别】:硕士
【学位授予年份】:2014
【分类号】:TU831
【共引文献】
相关会议论文 前10条
1 苏鹏;喻李葵;;转轮除湿空调系统研究进展[A];中国建筑学会建筑热能动力分会第十六届学术交流大会论文集[C];2009年
2 赵新舟;桂晓春;;地面情报雷达天线阵面除湿技术研究[A];2008年电子机械与微波结构工艺学术会议论文集[C];2008年
3 焉丽霞;施秀琴;王术香;郭亮;;温湿度独立控制系统新风除湿机的研制[A];2007年山东省制冷空调学术年会论文集[C];2007年
4 李森生;丁云;刘秋新;;地板辐射供冷的舒适度研究[A];2008年铁路暖通空调学术年会论文专辑[C];2008年
5 胡中平;刘秋新;;液体除湿空调性能的研究[A];2008铁路暖通空调学术年会论文集[C];2008年
6 张立志;;一种亲水/憎水双极膜的全热交换器传热传质特性[A];全国暖通空调制冷2006年学术年会文集[C];2006年
7 北京市建筑设计研究院课题组;;《建筑节能设计方法与模拟分析软件的实际检验》课题成果综述[A];2009年全国节能与绿色建筑空调技术研讨会暨北京暖通空调专业委员会第三届学术年会论文集[C];2009年
8 北京市建筑设计研究院课题组;;“建筑节能设计方法与模拟分析软件的实际检验”课题成果综述[A];全国暖通空调制冷2010年学术年会学术文集[C];2010年
9 李怀志;;关于核电站数据中心湿度控制的研究与应用[A];2013电力行业信息化年会论文集[C];2013年
10 田向宁;丁德;杨毅;李宁;;空气冷却除湿过程的理论研究[A];2013浙江省暖通空调动力学术年会、杭州市暖通空调学术年会论文集[C];2013年
相关博士学位论文 前10条
1 宋鹏;铂铝合金粘结涂层的高温氧化行为研究[D];昆明理工大学;2010年
2 朱继保;细颗粒物的电收集技术研究[D];浙江大学;2010年
3 李社锋;低挥发份劣质燃料循环流化床燃烧特性研究[D];浙江大学;2010年
4 赵佳飞;纳米流体辐射特性机理研究及其在太阳能电热联用系统中的应用研究[D];浙江大学;2009年
5 徐飞;脉冲放电电凝并结合碱液吸收烟气多种污染物协同脱除研究[D];浙江大学;2009年
6 刘小根;玻璃幕墙安全性能评估及其面板失效检测技术[D];中国建筑材料科学研究总院;2010年
7 魏永刚;晶格氧部分氧化甲烷制取合成气的基础研究[D];昆明理工大学;2008年
8 姜星莉;经济全球化背景下中国能源安全问题研究[D];武汉大学;2010年
9 杨波;基于并网逆变器电能质量与变换效率的若干关键技术研究[D];浙江大学;2010年
10 陈国志;电力谐波和间谐波参数估计算法研究[D];浙江大学;2010年
相关硕士学位论文 前10条
1 马丽君;固体干燥剂转轮除湿特性的理论与实验研究[D];天津商业大学;2011年
2 郭敬花;改性硅胶/分子筛复合物除湿性能研究[D];华南理工大学;2011年
3 刘红梅;聚偏氟乙烯膜的制备与疏水改性[D];华南理工大学;2011年
4 吕知梅;高性能吸湿剂的制备及吸附选择性研究[D];华南理工大学;2011年
5 朱晓华;热管除湿机设计与性能试验研究[D];南京师范大学;2011年
6 刘丽莹;植物气生根除湿探索性研究[D];重庆大学;2010年
7 林彦川;空调用填料除湿器性能的模拟研究[D];内蒙古科技大学;2011年
8 赵立峰;太阳能除湿系统应用于供暖/冷辐射地板的节能研究[D];上海电力学院;2011年
9 高强;无霜空气源热泵系统的实验研究[D];哈尔滨工业大学;2011年
10 唐正艳;开式冷水型转轮除湿空调实验研究与TRNSYS模拟优化[D];上海交通大学;2012年
本文编号:2181487