基于PEA测量技术的电缆外半导电层脉冲注入方式的影响因素
发布时间:2018-10-05 08:40
【摘要】:基于电声脉冲法(PEA)的同轴电缆空间电荷测量系统中,耦合的脉冲直接影响空间电荷的测量波形。因而简述了基于外半导电层脉冲注入法的同轴电缆空间电荷测量系统,测量了10 kV同轴电缆在不同接地点下的空间电荷波形。通过实验和仿真研究了不同接地点、不同电缆尺寸和不同脉冲注入区长度对脉冲注入波形的影响。实验与仿真结果表明:注入脉冲的波形对测量的空间电荷波形有直接的影响,当脉冲由外半导电层注入电缆时,外半导电层的阻抗特性会影响脉冲的注入效果。同时,同轴电缆的接地点和尺寸影响着脉冲的注入,接地点与脉冲注入点的距离越远,耦合脉冲幅值越高。此外,外绝缘层直径对外半导电层等效电阻值也有影响。
[Abstract]:In the space charge measurement system of coaxial cable based on electroacoustic pulse method (PEA), the coupling pulse directly affects the waveform of space charge measurement. Therefore, the space charge measurement system of coaxial cable based on the pulse injection method of outer semiconductive layer is briefly described. The space charge waveforms of 10 kV coaxial cable at different grounding points are measured. Through experiments and simulations, the effects of different connection locations, different cable sizes and different pulse injection region length on the pulse injection waveform are studied. The experimental and simulation results show that the waveform of the injected pulse has a direct effect on the measured space charge waveform. When the pulse is injected into the cable by the outer semi-conductive layer, the impedance characteristics of the outer semi-conductive layer will affect the injection effect of the pulse. At the same time, the location and size of the coaxial cable affect the pulse injection. The longer the distance between the connection point and the pulse injection point, the higher the coupling pulse amplitude. In addition, the equivalent resistance of the external semi-conductive layer has an effect on the diameter of the outer insulating layer.
【作者单位】: 西安交通大学电力设备电气绝缘国家重点实验室;南方电网科学研究院有限责任公司;
【基金】:国家自然科学基金(51377131)~~
【分类号】:TM248.3
本文编号:2252727
[Abstract]:In the space charge measurement system of coaxial cable based on electroacoustic pulse method (PEA), the coupling pulse directly affects the waveform of space charge measurement. Therefore, the space charge measurement system of coaxial cable based on the pulse injection method of outer semiconductive layer is briefly described. The space charge waveforms of 10 kV coaxial cable at different grounding points are measured. Through experiments and simulations, the effects of different connection locations, different cable sizes and different pulse injection region length on the pulse injection waveform are studied. The experimental and simulation results show that the waveform of the injected pulse has a direct effect on the measured space charge waveform. When the pulse is injected into the cable by the outer semi-conductive layer, the impedance characteristics of the outer semi-conductive layer will affect the injection effect of the pulse. At the same time, the location and size of the coaxial cable affect the pulse injection. The longer the distance between the connection point and the pulse injection point, the higher the coupling pulse amplitude. In addition, the equivalent resistance of the external semi-conductive layer has an effect on the diameter of the outer insulating layer.
【作者单位】: 西安交通大学电力设备电气绝缘国家重点实验室;南方电网科学研究院有限责任公司;
【基金】:国家自然科学基金(51377131)~~
【分类号】:TM248.3
【相似文献】
相关期刊论文 前4条
1 吕亮;雷琅;张晋;郭磊;李彦明;;电缆绕组变压器外半导电层中的电流特性[J];电工技术学报;2009年05期
2 马文忠;李耀华;孔力;;高压电机绕组电缆特性研究[J];高电压技术;2006年03期
3 牟磊;刘家齐;王晶;李彦明;;XLPE电缆绕组芯线与外半导电层间的暂态耦合特性[J];高电压技术;2005年11期
4 刘家齐;牟磊;贾磊;李彦明;;外半导电层对地电容与XLPE电缆绕组暂态特性[J];高电压技术;2005年11期
相关会议论文 前1条
1 高超飞;仰文林;尹德强;刘磊;;PEA法测量电缆空间的基本原理及应用[A];山东电机工程学会2012年度学术年会论文集[C];2012年