衰减全反射红外光谱法测定溶聚丁苯橡胶的微观结构
发布时间:2019-04-09 08:20
【摘要】:以溶聚丁苯橡胶(SSBR)为标准试样,通过涂膜红外光谱(IR)法确定了4种牌号(2557 S、2564、3840、553)SSBR微观结构含量的标称值,采用衰减全反射(ATR)-IR法测定了SSBR的微观结构含量,并与核磁共振(NMR)法测试结果进行了对比。结果表明,4种牌号SSBR标准试样的反式-1,4-结构、乙烯基结构、顺式-1,4-结构和苯乙烯结构的标称值(质量分数)分别为17.2%、15.8%、25.2%、19.5%,42.0%、37.6%、12.6%、42.6%,23.4%、20.4%、23.6%、23.1%,17.4%、26.1%、38.6%、14.8%。当平整光滑的试样厚度不大于2 mm时测试结果有较好的重复性,ATR-IR法测试结果与NMR法无显著性差异,准确性得到验证。
[Abstract]:Using (SSBR) as standard sample, the nominal values of SSBR microstructure content of four grades (2557 S, 2564, 3840553) were determined by (IR) method. The microstructure of SSBR was determined by attenuated total reflection (ATR)-IR and compared with that of nuclear magnetic resonance (NMR). The results showed that the nominal values (mass fraction) of trans-1, 4-structure, vinyl structure, cis-1, 4-structure and styrene structure of four SSBR standard samples were 17.2%, 15.8%, 25.2%, 19.5%, respectively, and the content of trans-1,4 -, vinyl, cis-1,4-and styrene were 17.2%, 15.8%, 25.2%, 19.5%, respectively. 42.0%, 37.6%, 12.6%, 42.6%, 23.4%, 20.4%, 23.6%, 23.1%, 17.4%, 26.1%, 38.6%, 14.8%. When the thickness of the smooth sample is less than 2 mm, the test results have good repeatability. There is no significant difference between the ATR-IR method and the NMR method, and the accuracy is verified.
【作者单位】: 中国石油兰州化工研究中心国家合成橡胶质量监督检验中心;
【分类号】:O657.33;TQ333.1
本文编号:2454993
[Abstract]:Using (SSBR) as standard sample, the nominal values of SSBR microstructure content of four grades (2557 S, 2564, 3840553) were determined by (IR) method. The microstructure of SSBR was determined by attenuated total reflection (ATR)-IR and compared with that of nuclear magnetic resonance (NMR). The results showed that the nominal values (mass fraction) of trans-1, 4-structure, vinyl structure, cis-1, 4-structure and styrene structure of four SSBR standard samples were 17.2%, 15.8%, 25.2%, 19.5%, respectively, and the content of trans-1,4 -, vinyl, cis-1,4-and styrene were 17.2%, 15.8%, 25.2%, 19.5%, respectively. 42.0%, 37.6%, 12.6%, 42.6%, 23.4%, 20.4%, 23.6%, 23.1%, 17.4%, 26.1%, 38.6%, 14.8%. When the thickness of the smooth sample is less than 2 mm, the test results have good repeatability. There is no significant difference between the ATR-IR method and the NMR method, and the accuracy is verified.
【作者单位】: 中国石油兰州化工研究中心国家合成橡胶质量监督检验中心;
【分类号】:O657.33;TQ333.1
【相似文献】
相关期刊论文 前1条
1 柳明珠,彭树馥,李权,吴靖嘉,李之辉,姚自余;溶聚丁苯橡胶某些溶液性质的研究[J];合成橡胶工业;1989年04期
相关硕士学位论文 前1条
1 刁飞玉;纳米金属氧化物光电材料的制备、微观结构及其物理化学性能研究[D];青岛大学;2015年
,本文编号:2454993
本文链接:https://www.wllwen.com/kejilunwen/huaxue/2454993.html
教材专著