水平剖分多级式离心泵打量下降分析及处理
发布时间:2018-10-05 14:20
【摘要】:水平剖分多级式离心水泵广泛的运用在热电及化工等各个行业,但在长期的运行过程中会出现流量、压力逐渐下降的现象,给生产用户带来不小的困扰。结合泸天化合成氨老系统P125锅炉给水泵流量、压力下降的典型案例来剖析造成多级离心给水泵流量、压力下降的原因及处理方法。
[Abstract]:Horizontal split multistage centrifugal pump is widely used in many industries, such as thermoelectricity and chemical industry, but in the long-term operation process, the flow rate will appear, the pressure will gradually decline, to the production users to bring a lot of trouble. Combined with the typical cases of water supply pump flow and pressure drop of P125 boiler in the old system of Lutianhua ammonia synthesis, the causes and treatment methods of the multistage centrifugal feed water pump flow and pressure drop are analyzed.
【作者单位】: 泸天化股份公司机械维修部;
【分类号】:TH311
本文编号:2253722
[Abstract]:Horizontal split multistage centrifugal pump is widely used in many industries, such as thermoelectricity and chemical industry, but in the long-term operation process, the flow rate will appear, the pressure will gradually decline, to the production users to bring a lot of trouble. Combined with the typical cases of water supply pump flow and pressure drop of P125 boiler in the old system of Lutianhua ammonia synthesis, the causes and treatment methods of the multistage centrifugal feed water pump flow and pressure drop are analyzed.
【作者单位】: 泸天化股份公司机械维修部;
【分类号】:TH311
【相似文献】
相关期刊论文 前6条
1 李思鼎,陈国安;工程机械液压系统内漏故障的诊断及预防[J];建筑机械;1998年03期
2 吴真光;刘波;;应用声发射法定量检测阀门内漏的可行性研究[J];科技创新导报;2011年34期
3 邱长安;水泵内漏的修复[J];农机维修;1994年06期
4 马效军;王丽红;丁连江;;液压系主要部件内漏的原因及处理[J];农机使用与维修;2008年03期
5 王梁,牛少华;液压系主要部件内漏的原因及处理[J];农机维修;2000年01期
6 ;[J];;年期
相关会议论文 前1条
1 赵清文;张相斐;高建国;;空压机段间冷却器内漏原因分析及处理[A];2003年晋冀鲁豫鄂蒙川沪云贵甘十一省市区机械工程学会学术年会论文集(河南分册)[C];2003年
相关博士学位论文 前1条
1 张颖;阀门气体内漏的声学特性及量化检测技术研究[D];大庆石油学院;2007年
相关硕士学位论文 前3条
1 王兵;阀门内漏的声场数值模拟及实验研究[D];大庆石油学院;2007年
2 张艺瀚;液体输送管道阀门内漏监测方法实验研究[D];北京化工大学;2015年
3 王新颖;承压阀门内漏声学检测方法研究[D];大庆石油学院;2004年
,本文编号:2253722