基于PCA的土壤源热泵系统地埋管泄漏检测与故障诊断
发布时间:2018-01-20 02:29
本文关键词: 土壤源热泵系统 地埋管 泄漏检测 主成分分析 故障诊断 出处:《建筑科学》2014年12期 论文类型:期刊论文
【摘要】:地埋管换热系统是土壤源热泵系统的关键组成部分,地埋管泄漏会影响土壤源热泵系统的稳定运行。针对土壤源热泵系统地埋管的泄露问题,本研究给出了1种基于主成分分析法的泄漏检测与故障诊断方法。本研究利用主成分分析法对土壤源热泵系统正常数据建模,将运行数据空间分为主成分子空间和残差子空间。利用SPE指标检测地埋管泄漏故障,利用SVI指标辨识故障和寻找故障源。最后,利用实际土壤源热泵系统运行数据验证了该泄漏检测与故障诊断方法的正确性和有效性。
[Abstract]:Geothermal pipe heat transfer system is a key component of ground-source heat pump system. The leakage of underground pipe will affect the steady operation of ground-source heat pump system. In this study, a method of leakage detection and fault diagnosis based on principal component analysis (PCA) is presented. In this study, the normal data of GSHP system are modeled by PCA. The operation data space is divided into principal component subspace and residual subspace. The SPE index is used to detect the leakage fault of buried pipe, and the SVI index is used to identify the fault and find the fault source. Finally. The validity and validity of the leakage detection and fault diagnosis method are verified by the operation data of the ground source heat pump system.
【作者单位】: 河南工业大学土木建筑学院;
【基金】:“十二五”国家科技攻关项目“浅层地热能集成应用技术与评估及示范”(2011BAJ03B09)
【分类号】:TU831
【正文快照】: 0引言土壤源热泵系统是1种利用浅层地热资源的高效节能空调系统,一般由地埋管换热系统、水源热泵机组和空调末端系统组成,其中地埋管系统是土壤源热泵系统的关键组成部分。虽然地埋管换热系统有着严格的设计、施工和验证标准,但是长期连续运行的地埋管系统经常会出现泄漏故障
【参考文献】
相关期刊论文 前1条
1 王海涛;刘倩;陈桂香;王军;王海霞;陈雁;;粮情监控系统中传感器故障诊断和数据恢复[J];中国粮油学报;2013年11期
【二级参考文献】
相关期刊论文 前6条
1 陆檩;高珊;李怡;闵新力;王贵甫;;粮情监控系统的设计与实现[J];计算机工程;2011年12期
2 张英;邓文斌;郑绍锋;;高大平房仓储粮害虫分布与发生初步调查[J];粮油仓储科技通讯;2012年03期
3 靳祖训;;中国粮食储藏科学技术成就与理念创新[J];粮油食品科技;2011年01期
4 隋明波;;机械通风对粮食安全储藏的作用及影响[J];中国科技信息;2010年04期
5 雷玲;孙辉;姜薇莉;白石桥;;稻谷储存过程中品质变化研究[J];中国粮油学报;2009年12期
6 苏宪庆;;移动无线通讯技术在远程粮情实时数据传输中的应用[J];中国粮油学报;2006年03期
【相似文献】
相关期刊论文 前10条
1 法智彤;褚晓丽;;浅谈土壤源热泵系统的发展及其应用[J];山西建筑;2010年08期
2 张玲;黄奕l,
本文编号:1446478
本文链接:https://www.wllwen.com/kejilunwen/sgjslw/1446478.html