当前位置:主页 > 科技论文 > 石油论文 >

W型火焰锅炉水冷壁大面积变形的仿真分析及治理

发布时间:2018-06-22 01:27

  本文选题:W型火焰锅炉 + 水冷壁管变形 ; 参考:《华东理工大学》2017年硕士论文


【摘要】:本文针对某热电公司600MW "W"型火焰锅炉前墙水冷壁多处出现大面积变形的情况,运用有限元仿真方法进行了热分析、稳定性分析和燃烧分析,根据分析结果总结出导致水冷壁变形的因素并提出合理化建议,对于锅炉的安全稳定运行具有实际指导意义。首先在ANSYS软件中使用APDL编程方法建立水冷壁的二维有限元数值模型,分析水冷壁在无垢、外壁结垢和内壁结垢三种工况下的温度场分布规律,比较三种工况下温度分布的不同之处,结果表明内壁结垢会使管壁温度显著升高。进一步建立水冷壁三维模型,合理简化模型和边界条件,分析其在三种工况下的温度、变形和应力分布特点。其温度场分析结果与二维模型下相吻合,内壁结垢是引起水冷壁管过热的主要因素。变形分析结果表明内壁结垢会最大程度地阻碍水冷壁管屏向下释放热变形,同时垂直于管屏方向的变形量也显著增大。应力分析结果表明,内壁结垢会造成垢层区域应力显著增大,并引起垢层上方区域的应力增大。在热应力分析的基础上,本文又对三种工况下的管屏进行了特征值屈曲分析,与无垢工况下相比,外壁结垢工况下的稳定性系数和模态无明显变化。内壁结垢时,稳定系数显著减小,并且失稳模态也有不同之处。结合之前的热分析结果说明内壁结垢引起水冷壁的变形可能性最大,需要对水冷壁除垢。最后利用Fluent软件对锅炉进行燃烧模拟。通过分析炉内温度场、速度场以及过量空气系数分布,发现燃烧中心偏高,配风比需调整,针对发现的不足提出增大乏气进气速度等合理性建议。本文分析方法及结论为解决电厂锅炉同类问题提供了参考。
[Abstract]:In this paper, thermal analysis, stability analysis and combustion analysis of the front wall of 600MW "W" flame boiler with finite element simulation method are carried out in view of the large area deformation of the front wall of a 600MW "W" flame boiler. According to the analysis results, the factors leading to the deformation of the water wall are summarized and some reasonable suggestions are put forward, which is of practical significance for the safe and stable operation of the boiler. Firstly, the two-dimensional finite element numerical model of water wall is established by using APDL programming method in ANSYS software, and the distribution of temperature field of water wall under three working conditions of no scale, outside wall scaling and inner wall scaling is analyzed. The difference of temperature distribution in three conditions is compared. The results show that the inner wall scaling can make the tube wall temperature increase significantly. Furthermore, the three-dimensional model of water wall is established, the model and boundary conditions are reasonably simplified, and the characteristics of temperature, deformation and stress distribution under three working conditions are analyzed. The results of temperature field analysis are in good agreement with the two-dimensional model, and the scaling of the inner wall is the main factor that causes the water wall tube to overheat. The results of deformation analysis show that the scaling of the inner wall will hinder the downward release of thermal deformation to the maximum extent, and the amount of deformation perpendicular to the tube panel will increase significantly. The results of stress analysis show that scaling on the inner wall will cause the stress of the scale layer to increase significantly and the stress of the area above the scale layer will increase. On the basis of thermal stress analysis, the eigenvalue buckling analysis of the tube screen under three conditions is carried out. The stability coefficient and mode of the outer wall under the scaling condition are not obviously changed compared with those under the non-scale condition. When the inner wall is fouled, the stability coefficient decreases significantly, and the instability modes are different. Combined with the results of thermal analysis before, it is shown that the possibility of water wall deformation caused by scaling on the inner wall is the greatest, and the scale removal of the water wall is needed. Finally, the boiler combustion simulation is carried out by fluent software. By analyzing the temperature field, velocity field and excess air coefficient distribution in the furnace, it is found that the combustion center is on the high side and the air distribution ratio needs to be adjusted. The methods and conclusions of this paper provide a reference for solving the similar problems of power plant boilers.
【学位授予单位】:华东理工大学
【学位级别】:硕士
【学位授予年份】:2017
【分类号】:TE963

【相似文献】

相关期刊论文 前10条

1 王国秋;防止水冷壁管爆破[J];劳动保护;1984年12期

2 余翔;郑志军;高岩;;水冷壁管爆裂分析[J];理化检验(物理分册);2007年08期

3 王文娟;一起锅炉的水冷壁管变形事故的原因分析[J];工业安全与防尘;1997年09期

4 贺红梅,崔朝英,李立明;火电厂水冷壁管腐蚀失效常见形式简介[J];理化检验(物理分册);2005年06期

5 杨峰;崔玮;韩福全;;火电厂锅炉水冷壁管横向裂纹开裂原因分析[J];热加工工艺;2011年05期

6 时军波;徐娜;陈立宗;马虹;张宏;;水冷壁管腐蚀破坏原因分析[J];热加工工艺;2013年16期

7 俞正千,张军孝,李文成;贵县糖厂碱回收炉更换水冷壁管及其材质分析鉴定[J];中国造纸;1988年03期

8 姜健;;一起蒸汽锅炉水冷壁管变形事故的分析[J];中国锅炉压力容器安全;2001年06期

9 何成,肖文彬;锅炉炉底水冷壁管爆管分析[J];理化检验(物理分册);2001年08期

10 徐洪;;渗铝水冷壁管失效的分析与处理[J];腐蚀与防护;2009年10期

相关会议论文 前10条

1 丁克勤;王洪柱;李娜;赵娜;黄冬林;;水冷壁管腐蚀多通道低频涡流检测仪器研制[A];中国力学学会学术大会'2009论文摘要集[C];2009年

2 李彦林;朱敏;聂常贵;龚亚军;;水冷壁管泄漏原因分析与防止对策[A];2006年第二届七省区市机械工程学会科技论坛暨学会改革与发展研讨会论文集[C];2006年

3 朱敏;;水冷壁管道失效分析[A];第四届全国压力容器学术会议论文集[C];1997年

4 伍昌鸿;李德暖;;1025t/h直流炉水冷壁过热爆管治理研究[A];全国火电大机组(300MW级)竞赛第36届年会论文集(上册)[C];2007年

5 郭小龙;;20~#钢水冷壁管爆破原因分析[A];冶金轧制过程自动化技术交流会论文集[C];2005年

6 李善风;;有裂纹的水冷壁管采用盐酸清洗技术[A];湖北省电机工程学会电厂化学专委会2007年学术年会论文集[C];2007年

7 詹约章;;燃煤锅炉水冷壁管烟侧腐蚀损坏及防护[A];第七届全国表面工程学术会议暨第二届表面工程青年学术论坛论文集(二)[C];2008年

8 李振华;;锅炉炉管爆破原因分析[A];全国材料理化测试与产品质量控制学术研讨会论文专辑(物理测试部分)[C];2002年

9 陈国杰;;CFB锅炉水冷壁磨损防护措施及质量控制[A];中国循环流化床发电生产运营管理(2013)[C];2013年

10 丁克勤;王洪柱;张旭;;水冷壁管腐蚀检测涡流阵列传感器设计与研制[A];第十二届全国实验力学学术会议论文摘要集[C];2009年

相关重要报纸文章 前1条

1 通讯员 龙蓉 方京 本报记者 彭展;25小时紧急接力[N];中国石化报;2010年

相关硕士学位论文 前7条

1 焦晓翠;超临界锅炉水冷壁管材的点蚀性能研究[D];长沙理工大学;2014年

2 陆海伟;1000MW燃煤机组水冷壁管腐蚀特性研究[D];长沙理工大学;2014年

3 张家维;国产超超临界垂直管圈水冷壁锅炉下水冷壁横向裂纹成因分析及综合治理[D];东北大学;2013年

4 杨存攀;W型火焰锅炉水冷壁大面积变形的仿真分析及治理[D];华东理工大学;2017年

5 郭林海;热电厂水冷壁管氢腐蚀失效及裂纹愈合研究[D];大连理工大学;2014年

6 彭哲言;热电站煤粉锅炉水冷壁爆管原因分析及预防措施研究[D];华东理工大学;2014年

7 张辉;不同水化学工况下金属氧化膜的特性研究[D];长沙理工大学;2011年



本文编号:2050926

资料下载
论文发表

本文链接:https://www.wllwen.com/kejilunwen/shiyounenyuanlunwen/2050926.html


Copyright(c)文论论文网All Rights Reserved | 网站地图 |

版权申明:资料由用户37c5b***提供,本站仅收录摘要或目录,作者需要删除请E-mail邮箱bigeng88@qq.com