数字摄影技术在尘肺诊断中的应用
发布时间:2018-07-29 12:52
【摘要】:对1205例确诊为矽肺的患者分别拍摄普通高仟伏(HkV)胸片和数字摄影(DR)对比分析诊断期别、小阴影形态、总体密集度,并观察不同kV、不同相机像素和窗位窗宽等投照条件对胸片尘肺病变、胸片黑白度、胸椎暴露程度的影响。所有诊断专家或不同诊断组对同一尘肺患者的DR胸片和HkV胸片诊断期别、小阴影形态、总体密集度的判定结果非常接近。用110 kV、120 kV所拍摄的DR胸片显示的肺纹理和病变边缘比用80 kV、90 kV拍摄的DR胸片要清晰;像素尺寸小、像素值越高的相机打印出的胸片其肺野外带肺纹理以及尘肺病变边缘更清晰、锐利,更利于观察。提示DR技术有利于提高胸片质量和尘肺病诊断准确率,建议尘肺的DR摄影以110~120 kV为宜,对相机的像素也应作出具体的要求。
[Abstract]:1205 patients with silicosis were compared with conventional high KV (HkV) chest radiographs and digital (DR) to analyze the diagnostic period, the shape of small shadows, and the overall density. The effects of different camera pixels and window width on pneumoconiosis, black-and-white degree of chest film and exposure degree of thoracic vertebrae were observed. The results of Dr chest radiographs and HkV chest radiographs of the same pneumoconiosis patients were similar to those of all diagnostic experts or different diagnostic groups. The lung texture and lesion edge of Dr chest radiographs taken with 110 kV or 120 kV radiographs were clearer than those of Dr chest films taken with 80 kV or 90 kV radiographs. The smaller pixel size and the higher the pixel value, the clearer the lung texture and the edge of pneumoconiosis. Sharpness is easier to observe. Dr technique is helpful to improve the quality of chest radiographs and the diagnostic accuracy of pneumoconiosis. It is suggested that 110 ~ 120kV should be used in Dr photography of pneumoconiosis, and the pixel of camera should be required.
【作者单位】: 广西壮族自治区职业病防治研究院;
【基金】:广西自然科学基金资助项目(桂科自0991224)
【分类号】:R135.2
本文编号:2152732
[Abstract]:1205 patients with silicosis were compared with conventional high KV (HkV) chest radiographs and digital (DR) to analyze the diagnostic period, the shape of small shadows, and the overall density. The effects of different camera pixels and window width on pneumoconiosis, black-and-white degree of chest film and exposure degree of thoracic vertebrae were observed. The results of Dr chest radiographs and HkV chest radiographs of the same pneumoconiosis patients were similar to those of all diagnostic experts or different diagnostic groups. The lung texture and lesion edge of Dr chest radiographs taken with 110 kV or 120 kV radiographs were clearer than those of Dr chest films taken with 80 kV or 90 kV radiographs. The smaller pixel size and the higher the pixel value, the clearer the lung texture and the edge of pneumoconiosis. Sharpness is easier to observe. Dr technique is helpful to improve the quality of chest radiographs and the diagnostic accuracy of pneumoconiosis. It is suggested that 110 ~ 120kV should be used in Dr photography of pneumoconiosis, and the pixel of camera should be required.
【作者单位】: 广西壮族自治区职业病防治研究院;
【基金】:广西自然科学基金资助项目(桂科自0991224)
【分类号】:R135.2
【相似文献】
相关期刊论文 前4条
1 邹伟明;廖分石;黄桂雄;廖列平;汤永中;李和林;叶绍色;;数字X射线摄影技术在矽肺病诊断中的应用探讨[J];中国职业医学;2008年05期
2 曹喜林;马媛媛;;数字摄影如何降低受检者辐射剂量[J];生物医学工程与临床;2010年05期
3 申永来;刘尚军;;尘肺影像诊断技术的研究进展[J];医学影像学杂志;2008年08期
4 刘建军;程金生;王艳;凌光华;张奇志;杨芬芳;陈东辉;苏旭;;湖南省不同管电压胸部X射线摄影所致受检者入射体表剂量比较[J];中国医学装备;2008年02期
相关会议论文 前2条
1 曹喜林;胡兵;马媛媛;;数字摄影中如何降低受检者照射剂量[A];2009中华医学会影像技术分会第十七次全国学术大会论文集[C];2009年
2 刘尚军;;尘肺影像诊断技术的研究进展[A];2008年全国职业性呼吸系统疾病学术研讨会论文集[C];2008年
相关硕士学位论文 前1条
1 信瑞;DR与CR检测人群受照剂量研究[D];吉林大学;2008年
,本文编号:2152732