磁共振在乳腺癌术后复查中的临床应用价值探讨
本文选题:乳腺癌 + 术后复查 ; 参考:《首都医科大学》2017年硕士论文
【摘要】:目的:本研究以病理和临床为对照,探讨磁共振成像技术在乳腺癌术后是否复发诊断及鉴别诊断价值,同时寻找判断乳腺癌术后是否复发的最佳扫描序列。材料与方法:选取2010年1月-2016年12月期间在我院同时行乳腺癌术后MRI和超声复查的女性患者52例(复查时患者平均年龄56.5岁,复查距手术平均时间为48.3个月)。以病理和临床为对照,回顾性分析MRI、超声两种检查方法在诊断乳腺癌是否复发时的敏感度、特异度,以及影像检查结果与病理临床结果的一致性;并分析不同MRI扫描序列在诊断乳腺癌术后是否复发中的价值。结果:52例患者中,MRI诊断为复发24例,经手术病理证实23例,误诊一例,MRI诊断为瘢痕形成或未见复发29例,全部经随访或手术证实无复发。超声诊断为复发23例,其中5例经随访无复发,超声诊断为无复发29例,其中5例漏诊复发。MRI、超声检查的敏感度分别为100%、78.3%,特异度分别为96.5%、82.8%,准确性分别为98.1%、80.8%。MRI与病理随访资料的一致性较好(MRI、超声诊断kappa值分别为0.961、0.61)。MRI图像中,动态增强早期出现强化病灶表现与乳腺癌复发的符合程度最高(kappa值为0.961)。结论:MRI在判断乳腺癌术后复发和瘢痕中具有很高的准确性,与临床病理结果的一致性优于超声检查,可以作为乳腺癌术后的常规检查手段。同时,磁共振动态增强扫描对乳腺癌复发的检出意义最大。
[Abstract]:Objective: to investigate the value of magnetic resonance imaging (MRI) in the diagnosis and differential diagnosis of postoperative recurrence of breast cancer, and to find out the best scan sequence for judging the recurrence of breast cancer. Materials and methods: from January 2010 to December 2016, 52 female patients with breast cancer underwent MRI and ultrasound examination simultaneously (mean age was 56.5 years), and the average time from reexamination to operation was 48.3 months. The sensitivity, specificity and consistency of MRI and ultrasonography in the diagnosis of breast cancer recurrence were analyzed retrospectively. The value of different MRI sequences in the diagnosis of postoperative recurrence of breast cancer was analyzed. Results among 52 cases, 24 cases were diagnosed as recurrence by MRI, 23 cases were proved by operation and pathology, 29 cases were diagnosed as scar formation or no recurrence by misdiagnosis by MRI. No recurrence was confirmed by follow-up or operation. Among the 23 cases diagnosed by ultrasound, 5 cases had no recurrence and 29 cases had no recurrence after follow up. Among them, the sensitivity of ultrasound examination was 100 and 78.3, the specificity was 96.5and 82.8, the accuracy was 98.1and 80.8.MRI was consistent with the pathological follow-up data. The kappa value of ultrasonography was 0.961and 0.61MRI, respectively, in MRI images, the sensitivity of ultrasonography was 78.3%, the specificity was 96.5% and 82.8%, and the accuracy was 98.1 and 80.8%, respectively. Dynamic contrast enhanced early enhanced lesions had the highest coincidence with breast cancer recurrence, and the kappa value was 0.961g. Conclusion Mr imaging has a high accuracy in judging the recurrence and scar of breast cancer after operation, and the consistency with clinicopathological results is superior to that of ultrasound, and it can be used as a routine examination method for breast cancer after operation. At the same time, dynamic contrast enhanced MRI is the most important in the detection of breast cancer recurrence.
【学位授予单位】:首都医科大学
【学位级别】:硕士
【学位授予年份】:2017
【分类号】:R737.9;R445.2
【参考文献】
相关期刊论文 前10条
1 ;中国抗癌协会乳腺癌诊治指南与规范(2015版)[J];中国癌症杂志;2015年09期
2 郑春鹏;林黛英;傅俊惠;吴智勇;;乳腺癌保乳术后随访高频彩超与磁共振的比较[J];实用医学杂志;2014年24期
3 朱思吉;沈坤炜;;乳腺癌术后随访策略的现状与争议[J];中华外科杂志;2014年10期
4 杨倩;朱庆莉;姜玉新;戴晴;;乳腺癌改良根治术后局部胸壁复发的临床特征与超声表现[J];中华医学超声杂志(电子版);2013年08期
5 黄哲宙;陈万青;吴春晓;郑荣寿;陈建国;杨念念;王宁;张思维;郑莹;;中国女性乳腺癌的发病和死亡现况——全国32个肿瘤登记点2003—2007年资料分析报告[J];肿瘤;2012年06期
6 林建华;谭理连;何伟红;黄勇;李敏红;邬恒夫;;全身弥散加权成像与同位素骨扫描诊断乳腺癌骨转移对比研究[J];放射学实践;2011年10期
7 郏潜新;宦怡;徐俊卿;欧阳林;陈懿;岳翠;肖玉辉;何平;;磁共振扩散加权成像在乳腺癌保乳术后随访的应用[J];医学影像学杂志;2011年06期
8 周纯武;张仁知;;MRI随访在乳腺癌诊断和疗效评估中的价值[J];磁共振成像;2011年03期
9 陈建伟;王杰;刘标;丁其勇;黄庆娟;;PET/CT与胸部诊断CT在乳腺癌术后随访中的比较[J];南京医科大学学报(自然科学版);2010年02期
10 靳二虎;吴晓华;梁宇霆;李辉;孙楠;贺文;马大庆;;3.0T MRI诊断和化疗后评估乳腺癌的可行性研究[J];中国医学影像技术;2008年07期
,本文编号:1830868
本文链接:https://www.wllwen.com/yixuelunwen/zlx/1830868.html