某小型数据中心散热用泵驱动回路热管换热机组的应用研究
发布时间:2018-05-20 23:01
本文选题:数据中心散热 + 泵驱动回路热管 ; 参考:《北京工业大学学报》2015年03期
【摘要】:由于泵驱动回路热管换热机组具有低耗能、高能效比(EER)的特点,为了将该机组更好地应用于小型数据中心,对某小型数据中心散热用泵驱动回路热管换热机组的运行性能进行研究,拟合出其换热特性曲线,并通过拟合曲线对其进行节能性分析.分析结果表明,在过渡季节及冬季,当室外温度低于15℃时,采用氟泵系统对数据中心机房进行散热能满足室内负荷要求并具有良好的节能效果,与之前的采用空调散热相比节省电能至少达到36.57%.
[Abstract]:Because the heat pipe heat exchanger of pump drive circuit has the characteristics of low energy consumption and high energy efficiency ratio (EER), in order to better apply this unit to small data center, The operation performance of heat pipe heat exchanger in pump driving circuit of a small data center is studied, and the heat transfer characteristic curve is fitted out, and the energy saving analysis is carried out through the fitting curve. The results show that in the transition season and winter, when the outdoor temperature is lower than 15 鈩,
本文编号:1916607