罕遇地震下部分框支生态复合墙结构破坏模式分析
[Abstract]:Part of the frame supported ecological composite wall structure is a new type of structure which uses frame-seismic wall structure at the bottom (part of the floor ecological composite wall or shear wall combined with the frame) and the upper part of the structure adopts the ecological composite wall structure. Because the self-weight of the upper ecological composite wall structure is relatively light, and the bearing capacity and stiffness of the ecological composite wall can be adjusted according to different design conditions, it is easy to realize the coordination of vertical stiffness of the building structure with large space at the bottom, and to reduce the earthquake damage effectively. Improve the overall seismic capacity of the structure. The reasonable failure mode can not only exert its large ductility through the bottom part of the frame support structure, but also make the components (block, rib and outer frame) in the upper wall play a primary and secondary role under the earthquake action. The multiple seismic lines of the structure are realized. Therefore, in this paper, three types of failure modes of ecological composite wall structure with frame support are discussed, and the factors influencing the failure mode of ecological composite wall structure with frame support are extended by using nonlinear numerical analysis software. It provides the basis for the design of the reasonable failure mode of the frame-supported ecological composite wall structure. The main contents of this paper are as follows: 1. Based on the experimental results of four two-span frame supported composite wall and beam structures, the concrete failure patterns and corresponding characteristics of each group of specimens are analyzed. Through the quantitative analysis of the strain value of steel bar, the location of plastic hinge is pointed out. Finally, it is proposed that the failure of three kinds of failure type .1 of the ecological composite wall structure with frame support is relatively uniform in the upper and lower structure of the transfer layer of the frame support transfer layer / 2 frame branch. (3) the failure occurred in the superstructure of the transfer story of the frame support. 2. According to the structural characteristics of the ecological composite wall with partial frame support, the elastoplastic model of the frame supported ecological composite wall beam was established by the nonlinear numerical analysis software SAP2000, which was composed of rigid frame and equivalent oblique brace. The results are compared with four two-span frame-supported ecological composite wall beams. The experimental study and numerical analysis show that the development of plastic hinge is in good agreement with the failure sequence of each member in the test. In the elastic-plastic stage, the equivalent diagonal bracing model can simulate the behavior of the partially frame-supported ecological composite wall structure more accurately. 3, based on the verified rigid-frame-equivalent inclined bracing model, A series of nonlinear numerical models of partially frame-supported ecological composite wall structures with varying stiffness ratio and floor number are established, and the influence of stiffness ratio and floor number on the failure mode of partially frame-supported ecological composite wall structures is presented. Numerical analysis shows that when the ratio of stiffness to ratio of 1 / 1 is greater than 1.5, the failure mode of frame-supported ecological composite wall structure is easy to occur when the stiffness ratio is less than 1.0, and when the stiffness ratio is less than 1.0, the failure mode of composite wall layer is easy to occur when the weak story of frame-supported ecological composite wall structure is moved up. When the stiffness ratio is between 1.5 and 1.0, the weak stiffness of the lower part of the transfer layer is relatively weak when the upper and lower structure of the transfer layer is destroyed relatively uniformly, and the weak layer of the lower frame branch is benefited by increasing the number of the upper floors of the transfer layer.
【学位授予单位】:西安建筑科技大学
【学位级别】:硕士
【学位授予年份】:2014
【分类号】:TU398.9;TU312.3
【相似文献】
相关期刊论文 前10条
1 ;新一代墙材——复合墙板[J];广东建材;2004年04期
2 李升才;;复合墙板轴心受压试验研究[J];华侨大学学报(自然科学版);2006年04期
3 杨伟静;刘淼;韩颂新;侯和涛;;轻型复合墙板的应用研究[J];新型建筑材料;2010年10期
4 邓宝仲;;复合墙板表面油污处理[J];建筑工人;1986年05期
5 徐峰;;复合墙板[J];建材工业信息;1990年19期
6 张同亿,于庆荣,吴敏哲,姜维山;复合墙板承载力的试验研究[J];建筑结构;2001年09期
7 张同亿,张兴虎,于庆荣;复合墙板结构层组合形式的探讨[J];西安建筑科技大学学报(自然科学版);2001年01期
8 韩静云,顾兴东;玻璃纤维增强水泥复合墙板的节点安装[J];混凝土与水泥制品;2002年05期
9 姜忻良;高海;许岩;张宇;;复合墙板计算模型与试点工程动力特性分析[J];地震工程与工程振动;2006年01期
10 李升才;王英华;;复合墙板受力性能平面有限元分析[J];建筑结构;2007年07期
相关会议论文 前10条
1 侯和涛;马克峰;李国强;;钢丝桁架复合墙板抗弯及振动特性试验研究[A];钢结构工程研究⑧——中国钢协结构稳定与疲劳分会第12届(ASSF-2010)学术交流会暨教学研讨会论文集[C];2010年
2 姚谦峰;周小真;;轻型复合墙板受力性能试验研究[A];第三届全国结构工程学术会议论文集(上)[C];1994年
3 时美微;;轻质实心复合墙板的应用与施工技术[A];2014年全国科技工作会议论文集[C];2014年
4 成全喜;杨德健;孙锦镖;王书祥;;混凝土夹芯复合墙板结构性能试验研究[A];第十届全国结构工程学术会议论文集第Ⅱ卷[C];2001年
5 王静峰;李金超;侯和涛;邱灿星;;节能夹层复合墙板与钢框架的协同工作与抗震性能[A];第六届全国防震减灾工程学术研讨会暨第二届海峡两岸地震工程青年学者研讨会论文集(Ⅱ)[C];2012年
6 张兴虎;张同亿;郭诚;;边框对复合墙板抗震性能影响的试验研究[A];第十届全国结构工程学术会议论文集第Ⅱ卷[C];2001年
7 王建强;姚谦峰;陈平;赵冬;袁泉;;密肋复合墙板变形与刚度分析[A];第十届全国结构工程学术会议论文集第Ⅱ卷[C];2001年
8 李晶晶;刘海宁;侯和涛;周健;;节能复合墙板的有限元分析[A];第23届全国结构工程学术会议论文集(第Ⅱ册)[C];2014年
9 周健;侯和涛;刘海宁;李晶晶;吴明磊;吕忠珑;;半刚接钢框架-复合墙板结构体系的滞回性能试验研究[A];钢结构工程研究(十)——中国钢结构协会结构稳定与疲劳分会第14届(ISSF-2014)学术交流会暨教学研讨会论文集[C];2014年
10 邓永胜;姜忻良;刘杰;;环保型高强石膏复合墙板体系抗震分析[A];第三届全国现代结构工程学术研讨会论文集[C];2003年
相关重要报纸文章 前4条
1 石吉图;新一代墙材:复合墙板[N];中华建筑报;2004年
2 周卫国 河北省墙改节能办副主任、高级工程师 周伊琳 德国达姆施塔特工业大学研究生;建筑承重墙板的应用与探索[N];中国建设报;2006年
3 记者 陈炜 通讯员 曹晓东 张早光;农民姚明起7年获8项发明专利[N];连云港日报;2011年
4 张维善 彭峰 胡浩;中山好城环保建材公司推出新一代植物纤维复合板[N];中国建材报;2005年
相关博士学位论文 前4条
1 马清珍;混凝土灌芯速成墙板结构体系弹塑性分析[D];天津大学;2010年
2 魏晓;框支密肋复合墙结构墙梁受力机理及结构抗震设计理论研究[D];西安建筑科技大学;2008年
3 张洪波;新型复合混凝土剪力墙结构体系研究[D];天津大学;2005年
4 张程华;中高层生态复合墙混合结构计算理论与设计方法研究[D];西安建筑科技大学;2013年
相关硕士学位论文 前10条
1 杨丹;硅酸钙/纸蜂窝复合墙板的性能研究[D];陕西科技大学;2015年
2 艾文;罕遇地震下部分框支生态复合墙结构破坏模式分析[D];西安建筑科技大学;2014年
3 蒋金梁;混凝土夹芯复合墙板热工和力学性能研究(夏热冬冷地区)[D];浙江大学;2008年
4 马克峰;钢结构住宅节能复合墙板的振动特性研究与风振分析[D];山东大学;2010年
5 宋美洁;复合墙板抗压性能试验研究[D];华侨大学;2009年
6 李智;钢筋型复合墙板及其连接受力性能研究[D];清华大学;2009年
7 张程华;新型复合墙结构简化计算模型研究[D];西安建筑科技大学;2010年
8 宋宁;砼密柱石膏复合墙板结构抗震性能研究[D];天津大学;2012年
9 赵丽君;寒冷地区绿色节能复合墙板的承载力研究[D];吉林建筑工程学院;2011年
10 曹慧;寒冷地区复合墙板工厂化生产的养护与成品保护技术研究[D];沈阳建筑大学;2013年
本文编号:2220231