温度对网格型次氯酸钠发生器运行效果的影响
发布时间:2018-11-10 07:44
【摘要】:结合自组装的网格型电极,试验研究次氯酸钠发生器在不同盐水温度、不同运行模式、有无冷却措施等情况下的运行效果。试验结果表明:降低电解槽内盐水温度可有效提高次氯酸钠发生器的电解效率。增设循环冷却水或间歇式运行可提高有效氯产量38%~42%、电流效率37%~65%,降低运行成本5.217~10.185元/kg。增设循环冷却水情况下有效氯产量最高可达263g,相应的理论运行成本为8.876元/kg;电解270~310min时,有效氯产量为235~250g,运行成本最低,为7.989~8.066元/kg。在实际应用中,应根据产氯量、运行成本等因素综合考虑电解时间。
[Abstract]:Combined with self-assembled grid electrode, the operation effect of sodium hypochlorite generator under different brine temperature, operation mode and cooling measures was studied. The results show that the electrolytic efficiency of sodium hypochlorite generator can be improved effectively by reducing the temperature of brine in the electrolytic cell. The addition of circulating cooling water or intermittent operation can increase the effective chlorine production by 38 and 42, and the current efficiency by 37 and 65, and reduce the operating cost by 5.217 yuan and 10.185 yuan / kg.. Under the condition of adding circulating cooling water, the maximum effective chlorine production can be up to 263 g. When the corresponding theoretical operating cost is 8.876 yuan / kg; electrolytic 270~310min, the effective chlorine output is 235 ~ 250g, and the operating cost is the lowest, 7.989 ~ 8. 066 yuan / kg.. In practical application, electrolysis time should be considered synthetically according to chlorine production, operation cost and so on.
【作者单位】: 中国灌溉排水发展中心(水利部农村饮水安全中心);中国水利水电科学研究院;
【基金】:国家“十二五”科技支撑项目“村镇应急水处理关键技术及设备研发”(2012BAJ25B04)
【分类号】:TU991.25
本文编号:2321835
[Abstract]:Combined with self-assembled grid electrode, the operation effect of sodium hypochlorite generator under different brine temperature, operation mode and cooling measures was studied. The results show that the electrolytic efficiency of sodium hypochlorite generator can be improved effectively by reducing the temperature of brine in the electrolytic cell. The addition of circulating cooling water or intermittent operation can increase the effective chlorine production by 38 and 42, and the current efficiency by 37 and 65, and reduce the operating cost by 5.217 yuan and 10.185 yuan / kg.. Under the condition of adding circulating cooling water, the maximum effective chlorine production can be up to 263 g. When the corresponding theoretical operating cost is 8.876 yuan / kg; electrolytic 270~310min, the effective chlorine output is 235 ~ 250g, and the operating cost is the lowest, 7.989 ~ 8. 066 yuan / kg.. In practical application, electrolysis time should be considered synthetically according to chlorine production, operation cost and so on.
【作者单位】: 中国灌溉排水发展中心(水利部农村饮水安全中心);中国水利水电科学研究院;
【基金】:国家“十二五”科技支撑项目“村镇应急水处理关键技术及设备研发”(2012BAJ25B04)
【分类号】:TU991.25
【相似文献】
相关期刊论文 前10条
1 吕士健;国标《次氯酸钠发生器》送审稿通过审查[J];中国给水排水;1989年06期
2 康华刚;;次氯酸钠发生器的选型[J];净水技术;1991年01期
3 庞巍;;降低次氯酸钠发生器使用成本的试验研究[J];西部探矿工程;2007年05期
4 李文;李晓琴;;电解法次氯酸钠发生器不同技术参数的研究[J];中国农村水利水电;2011年09期
5 高隆绪 ;范潇芳;;次氯酸钠发生器及投加方式的改进[J];建筑技术通讯(给水排水);1992年05期
6 李晓琴;贾燕南;胡孟;邬晓梅;宋卫坤;;电解参数对不同电极次氯酸钠发生器运行效果影响研究[J];中国农村水利水电;2014年02期
7 包松赢;次氯酸钠发生器[J];城市公用事业;2000年06期
8 孙凝;龚德洪;;次氯酸钠发生器在小型水厂的应用与成本研究[J];城镇供水;2014年01期
9 李晓琴;刘文朝;贾燕南;李连香;;无隔膜电解次氯酸钠发生器阴极材料的改进研究[J];水利水电技术;2011年12期
10 范潇芳;实用新型给水消毒器的应用[J];铁道标准设计;1998年10期
相关硕士学位论文 前1条
1 刘珂;次氯酸钠发生器技术的研究与应用[D];同济大学;2007年
,本文编号:2321835