装配整体式混凝土结构连接界面区氯离子传输特性
[Abstract]:The development of prefabricated buildings has become a national strategy in the field of architecture, and the assembly of integral concrete structures is still the main force. However, the durability of this kind of structure is seldom concerned. Due to the existence of physically discontinuous interface regions, a series of durability problems such as corrosion, corrosion and resistance degradation are caused. Therefore, the durability characteristics of the interface zone of assembled integral concrete structures are studied, which can enrich the durability theory of concrete structures and promote the application and development of assembly concrete structure technology. It is of great academic and engineering value to improve the low carbonization level of the whole life of the building structure. In this paper, based on the durability problem of monolithic concrete structure assembled in chloride environment, the key premise of physical discontinuity in new and old concrete interface region is grasped, and the fundamental problem of chloride transport behavior in the connection interface region is discussed. The corrosion characteristics and mechanism of chloride ion in precast and post-cast concrete interface zone under different interface roughness, different compressive stress and different crack width are revealed in the assembly integral concrete structure, so as to study the corrosion of reinforcement in the interface zone. The study of durability problems such as structural resistance degradation and structural life prediction is the foundation. The basic characteristics of the distribution and evolution of chloride ion concentration with space and time in the interfacial zone were obtained by means of three different interface roughness (average sand filling depth 1-2mm 6-7mm and 11-13mm) and two different erosion periods (60d ~ 180d). The results show that the concentration of chloride in the interfacial region is significantly higher than that in the non-interfacial region. Accordingly, the interfacial effect of chloride concentration distribution and its quantitative expression method (interfacial effect index) are defined. According to the analysis of the interfacial zone effect index, it is found that with the increase of erosion depth, the interfacial zone effect increases, the interfacial zone effect decreases with the increase of erosion time, and the influence of interfacial roughness on the interfacial zone effect shows the characteristics of two ends between middle and small. That is, the interfacial zone effect of 1-2mm and 11-13mm is close, and larger than that of 6-7mm. Three different compressive stresses (0 0. 4 fc) and two different erosion periods (60 d ~ 180 d) were used to study the dry and wet cycling erosion of chloride ions, and the results were analyzed by using the interface zone effect index defined above. The influence of compressive stress level on the distribution and evolution of chloride ions in the interface region is obtained. It is found that the existence of compressive stress decreases the interfacial zone effect, and the greater the compressive stress is, the smaller the interfacial zone effect is. On the other hand, the erosion of chloride ions in the interface area is aggravated. The dry and wet cycling erosion tests of chlorine ions under three different interface crack widths (0 ~ 50 mm ~ 200 mm) and two different erosion periods (60 d ~ 180 d) were carried out, and the results were analyzed by using the interfacial zone effect index defined above. The influence of cracking degree on the distribution and evolution of chloride ions in the interface region is obtained. It is found that the existence of cracks at the interface increases the interfacial effect of chloride ion transport, and the wider the crack width, the greater the degree of improvement.
【学位授予单位】:中国矿业大学
【学位级别】:硕士
【学位授予年份】:2017
【分类号】:TU37
【参考文献】
相关期刊论文 前10条
1 付传清;屠一军;金贤玉;张俊芝;;荷载作用对混凝土中氯盐传输的影响研究进展[J];硅酸盐学报;2015年04期
2 刘琼;李向民;许清风;;预制装配式混凝土结构研究与应用现状[J];施工技术;2014年22期
3 陆春华;张邵峰;刘荣桂;崔钊玮;;横向弯曲裂缝对混凝土内氯离子侵蚀作用的影响[J];土木建筑与环境工程;2013年06期
4 尹衍j;詹耀裕;黄绸辉;;台湾润泰预制工法介绍[J];混凝土世界;2013年09期
5 延永东;金伟良;王海龙;陆春华;;干湿交替作用下氯离子在开裂混凝土中的输运规律[J];中南大学学报(自然科学版);2013年05期
6 万小梅;苏卿;赵铁军;任心波;;单轴受压混凝土的微裂缝和氯离子侵入性[J];土木建筑与环境工程;2013年01期
7 张伟平;张庆章;顾祥林;钟丽娟;黄庆华;;环境条件和应力水平对混凝土中氯离子传输的影响[J];江苏大学学报(自然科学版);2013年01期
8 朱方之;赵铁军;姜福香;马志鸣;;荷载损伤后混凝土劣化机理和试验研究[J];工业建筑;2012年12期
9 郭冬梅;项贻强;程坤;林士旭;李威;;沿海混凝土桥氯离子扩散修正模型及其应用[J];中国公路学报;2012年05期
10 金祖权;赵铁军;陈惠苏;庄其昌;;海洋环境下裂缝混凝土氯盐腐蚀[J];中南大学学报(自然科学版);2012年07期
相关会议论文 前1条
1 高建明;余振新;宋鲁光;薛宝法;孙伟;;荷载和干湿交替耦合作用下混凝土抗氯离子侵蚀研究[A];2011年混凝土与水泥制品学术讨论会论文集[C];2011年
相关博士学位论文 前3条
1 黄慎江;二层二跨预压装配式预应力混凝土框架抗震性能试验与理论研究[D];合肥工业大学;2013年
2 付传清;混凝土中氯盐的传输机理及钢筋锈胀模型[D];浙江大学;2012年
3 李平先;新老混凝土粘结面抗冻和抗渗性能试验研究[D];大连理工大学;2004年
相关硕士学位论文 前10条
1 黄泓嘉;海洋环境中氯离子侵蚀作用下混凝土结构耐久性试验研究[D];长沙理工大学;2013年
2 常鹏飞;新旧混凝土界面的连接方法及动力性能研究[D];西安科技大学;2012年
3 徐可;不同干湿制度下混凝土中氯盐传输特性研究[D];三峡大学;2012年
4 齐广政;海洋大气环境下混凝土氯离子侵蚀性能的试验研究[D];西安建筑科技大学;2012年
5 聂红宇;开裂状态对氯离子环境中混凝土结构耐久性影响研究[D];中南大学;2012年
6 屈克达;预压装配式预应力混凝土结构承载力计算方法[D];合肥工业大学;2012年
7 彭智;干湿循环与荷载耦合作用下氯离子侵蚀混凝土模型研究[D];浙江大学;2010年
8 秦亮;装配整体式叠合连续楼板足尺加载试验研究[D];广州大学;2006年
9 李冰;新老混凝土粘结面渗透试验研究[D];郑州大学;2004年
10 张慧昕;沿海混凝土结构耐久性的成因、评估与质量控制[D];浙江大学;2002年
,本文编号:2189816