核电厂凝结水精处理系统特殊稳态运行探讨
发布时间:2018-01-11 22:17
本文关键词:核电厂凝结水精处理系统特殊稳态运行探讨 出处:《给水排水》2017年S2期 论文类型:期刊论文
更多相关文章: 核电 凝结水精处理系统 混床 守恒 四用一备 四用零备 特殊稳态
【摘要】:福清核电厂1号机组凝结水精处理系统因系统水压试验失当,造成五台混床出水装置出水孔板全部脱焊,导致五台混床均不可用。其中2#混床受损最严重,已经无法修复。采用守恒原理,结合当时福清核电厂1号机组二回路的实际情况,经计算得出:在凝结水精处理系统三台混床投用时,机组功率可升至75%FP;在凝结水精处理系统四台混床投用时,机组可满功率运行;凝结水精处理系统由四用一备正常运行模式改为四用零备的特殊稳态运行模式可以满足福清核电厂1号机组首次核燃料循环的需求。
[Abstract]:Due to the improper hydraulic test of the condensate treatment system of Unit 1 of Fuqing Nuclear Power Plant, the outlet plate of the outlet water of five mixed-bed units is completely dewelded, resulting in the unavailability of all the five mixed-bed units, in which the damage to the mixed-bed is the most serious. The principle of conservation is adopted and combined with the actual situation of the second loop of Unit 1 of Fuqing Nuclear Power Plant at that time, it is calculated that when the three mixed-bed are put into use in the condensate precision treatment system. Unit power can rise to 75 FP; When the four mixing beds are put into use in the condensate treatment system, the unit can operate at full power. The condensate fine treatment system can meet the needs of the first nuclear fuel cycle of Fuqing Nuclear Power Plant Unit 1 from the normal operation mode of four-use one-standby system to the special steady-state operation mode of four-use zero standby system.
【作者单位】: 中国核电工程有限公司华东分公司;
【分类号】:TM623.4
【正文快照】: 1 背景凝结水精处理系统(系统代码:ATE)为永久性设置的系统,用以除去凝结水中的离子态及悬浮状杂质,确保达到蒸汽发生器规定的给水水质。凝结水精处理主要由五台前置阳床,五台高速混床,两套完整的体外再生装置组成。前置阳床为两台相互备用的再生塔,可兼作树脂贮存塔;高速混
【相似文献】
相关期刊论文 前2条
1 李华;马燕;肖艳;刘月恒;杨永青;;西安脉冲堆水净化系统混床废树脂的性能变化[J];原子能科学技术;2010年01期
2 许美景,董黎明;秦山核电站二回路凝结水净化混床树脂再生试验[J];中国核科技报告;1995年00期
相关会议论文 前1条
1 张世伟;陈学德;马建中;;红沿河核电站混床除盐器抗震分析[A];四川省力学学会2010年学术大会论文集[C];2010年
,本文编号:1411465
本文链接:https://www.wllwen.com/kejilunwen/dianlidianqilunwen/1411465.html