当前位置:主页 > 科技论文 > 电气论文 >

氟塑料换热器传热特性实验研究与模型优化

发布时间:2018-01-22 06:54

  本文关键词: 氟塑料 换热器 传热模型优化 传热性能 实验研究 出处:《中国电机工程学报》2017年08期  论文类型:期刊论文


【摘要】:氟塑料换热器优良的耐腐蚀特性,为电厂低温烟气余热回收提供了新的解决途径。针对氟塑料换热器开展实验研究,氟塑料换热管束表面光滑对层流边界层的附加扰动较弱,管外对流传热系数较金属换热材料偏低。茹卡乌斯卡斯经典关联式直接应用于塑料换热器存在约40%偏差。结合风洞实验数据,得到换热器在不同风速下的总传热系数、管外对流传热系数、空气阻力特性和各环节热阻分布特性。
[Abstract]:The excellent corrosion resistance of fluoroplastic heat exchanger provides a new solution for waste heat recovery of low temperature flue gas in power plant. The additional disturbance of laminar boundary layer is weak when the surface of fluoroplastic tube bundle is smooth. The convection heat transfer coefficient outside the tube is lower than that of the metal heat transfer material. There is about 40% deviation in the application of the Rucauskas classical correlation formula to the plastic heat exchanger. The total heat transfer coefficient, the convection heat transfer coefficient outside the tube, the air resistance characteristics and the thermal resistance distribution characteristics of the heat exchanger at different wind speeds are obtained.
【作者单位】: 华北电力大学;大金氟化工(中国)有限公司;
【基金】:国家自然科学基金项目(51436006) 中央高校基本科研业务费专项基金(2015ZZD10)~~
【分类号】:TM621
【正文快照】: 0引言燃煤电站锅炉每年消耗约15亿吨标煤,约占全国煤炭消耗总量的50%[1]。为防止锅炉尾部部件发生低温腐蚀,锅炉排烟温度一般设计为120~150℃,排烟热损失占到锅炉全部热损失的一半以上,蕴藏着巨大的余热资源[2]。在实际运行中,由于工况改变、煤种变动、受热面灰污等原因,部分