当前位置:主页 > 科技论文 > 电气论文 >

水电站接地网暂态特性及其评估技术研究

发布时间:2018-02-21 22:12

  本文关键词: 接地网 暂态特性 冲击接地电阻 异质土壤 CDEGS 出处:《西南交通大学》2017年硕士论文 论文类型:学位论文


【摘要】:水电站受水能资源分布影响,大多位于高山峡谷地区,相对普通变电站而言,其土壤环境更为复杂,且水电站接地网由站内多个接地网组成,分布范围广、结构多样。对于接地系统而言,其冲击接地电阻、暂态地电位升等接地参数都与其所处的土壤环境、拓扑结构以及导体电气性能参数密不可分。本文针对水电站土壤结构复杂、接地网结构多样的特点,首先基于水平双层土壤模型、垂直双层土壤模型和局部异质土壤模型,分别研究了接地网暂态特性参数随各土壤特征参数的变化规律,根据仿真结果得出:水平双层土壤下,接地网冲击接地电阻随上层土壤电阻率的增大呈非线性增加,受底层土壤电阻率影响较小;垂直双层土壤下,接地网冲击接地电阻随雷电流注入一侧土壤电阻率的增大呈非线性增大,受另一侧土壤电阻率的影响较小;局部异质土壤下,当外围土壤电阻率一定时,随着异质土壤电阻率的增加接地网冲击接地电阻不断增加,异质土壤横截面越大,接地网的冲.击接地电阻越大,且其对接地网冲击接地电阻的影响越显著。然后针对水电站典型地网结构,仿真计算了存在垂直接地极的接地网和双层接地网的雷击暂态特性,发现在距离雷电流注入点一定范围内,随着接地极数量的增多,接地网冲击接地电阻下降越明显,采用外疏内密的方式敷设增加的垂直接地极来降低冲击接地电阻的效果最好;对于双层地网结构,上层接地网的雷电流注入点与连接导体越近,越有助于降低上层接地网导体的暂态电位,但会导致下层接地网导体的暂态电位升高,所以在布置接地引下线时应当充分考虑与上、下层接地网连接的一次、二次设备的绝缘性能。最后,针对某水电站220kV开关二次设备故障,搭建了接地网等比例模型,仿真计算了接地网故障区域导体的暂态电位分布以及雷击点附近接地网导体的暂态电位差,发现避雷针附近的接地网导体电位升高对一次设备绝缘的威胁不是很大,但雷电流注入点附近导体段的暂态电位差很大,超过了二次设备的绝缘耐受水平,建议在避雷针接地引下线处1m的范围内至少增加3根垂直接地极,或者将原避雷针的位置进行调整,建议将避雷针安装在距离变压器电缆就地端子箱大于15m的位置。
[Abstract]:Most hydropower stations are located in high mountains and canyons, the soil environment is more complex than ordinary substations, and the grounding grid of hydropower stations is composed of many grounding grids in the station, and the distribution range is wide. The grounding parameters such as impulse grounding resistance, transient ground potential rise and so on are closely related to the soil environment, topology and electrical properties of conductors. In this paper, the soil structure of hydropower stations is complex. Firstly, based on horizontal double-layer soil model, vertical double-layer soil model and local heterogeneous soil model, the variation of transient parameters of grounding grid with each soil characteristic parameter is studied respectively. According to the simulation results, the impact grounding resistance of grounding grid increases nonlinearly with the increase of the resistivity of the upper layer of soil, and is less affected by the resistivity of the bottom layer under the vertical double-layer soil. The impact grounding resistance of grounding grid increases nonlinearly with the increase of lightning current injection into one side of the soil, and is less affected by the other side of the soil resistivity, while in the local heterogeneous soil, when the peripheral soil resistivity is fixed, With the increase of the resistivity of the heterogeneous soil, the impact grounding resistance of the grounding grid increases continuously. The larger the cross section of the heterogeneous soil, the more the impact of the grounding grid. The impact of grounding resistance on ground grid is more significant. Then, the transient characteristics of lightning strike of grounding grid with vertical grounding pole and double-layer grounding grid are simulated and calculated for typical ground grid structure of hydropower station. It is found that within a certain range of distance from the lightning current injection point, with the increase of the number of grounding poles, the impact grounding resistance of the grounding grid decreases more obviously, and the increase of vertical grounding pole is the best way to reduce the impact grounding resistance. For the double-layer ground grid structure, the closer the lightning current injection point of the upper grounding grid is to the connecting conductor, the more helpful it is to reduce the transient potential of the upper grounding grid conductor, but it will lead to the increase of the transient potential of the lower grounding grid conductor. Therefore, the insulation performance of the primary and secondary equipment connected with the upper and lower grounding grids should be fully considered in the arrangement of grounding lead down lines. Finally, for the 220 kV secondary switchgear fault of a hydropower station, a proportional model such as grounding grid is built. The transient potential distribution of the conductors in the fault area of the grounding grid and the transient potential difference of the grounding grid conductors near the lightning strike point are simulated and calculated. It is found that the increase of the potential of the grounding grid conductors near the lightning rod is not a great threat to the insulation of the primary equipment. However, the transient potential difference in the conductor section near the lightning current injection point is very large, which exceeds the insulation tolerance level of the secondary equipment. It is suggested that at least three vertical earth poles should be added within 1 m below the lightning rod grounding lead. Or the location of the original lightning rod should be adjusted and the lightning rod should be installed in the position where the terminal box of the distance transformer cable is more than 15m.
【学位授予单位】:西南交通大学
【学位级别】:硕士
【学位授予年份】:2017
【分类号】:TV734;TM862

【相似文献】

相关期刊论文 前10条

1 王洪泽;论任意形状复合接地网接地电阻的计算问题[J];广西电力工程;2000年03期

2 王西平;330kV花园变人工接地网改造设计的理论核算[J];青海电力;2000年01期

3 王洪泽;复合接地网接地电阻的简化计算[J];电网技术;2001年08期

4 黄海鹏;接地网接地电阻的计算机仿真[J];广东输电与变电技术;2003年03期

5 刘渝根,滕永禧,陈先禄,袁涛;接地网导体状态的诊断方法[J];重庆大学学报(自然科学版);2004年02期

6 周秧;李勐;索春梅;周晓虎;王文德;;分层土壤中接地网参数的数值计算[J];东北电力大学学报;2006年04期

7 ;铜质接地网前景看好[J];大众用电;2007年01期

8 杨理民;;大型接地网接地电阻的测试[J];四川建筑;2007年S1期

9 梁春明;;变电所铜接地网与钢接地网比较[J];中国水能及电气化;2008年04期

10 付龙海;;水平双层土壤对接地网电气特性的影响[J];电气应用;2008年14期

相关会议论文 前10条

1 陈绍勇;;大面积水下网箱式立体接地网的研究与应用[A];四川、贵州、云南三省水电厂(站)机电设备运行技术研讨会论文集[C];2010年

2 陈锦云;杨铭泽;;接地网敷设方式对接地电阻实测值的影响[A];全国电网中性点接地方式与接地技术研讨会论文集[C];2005年

3 邵建人;向洪兵;杜继红;;交流系统接地网的腐蚀与防护研究[A];全国电网中性点接地方式与接地技术研讨会论文集[C];2005年

4 蔡崇积;;我国依国外标准设计电力交流接地网运行状况调研[A];全国电网中性点接地方式与接地技术研讨会论文集[C];2005年

5 梁清强;;蜂窝形接地网[A];全国电网中性点接地方式与接地技术研讨会论文集[C];2005年

6 陈智勇;孟骁勇;王运生;;阻频特性法在接地网测试中的应用[A];2006中国科协年会第三分会场论文集[C];2006年

7 米建卫;;立体接地网在500KV潍坊变电站的应用[A];山东电机工程学会第四届供电专业学术交流会论文集[C];2007年

8 蔡崇积;;电力交流接地网损坏原因调研与分析[A];全国电网中性点接地方式与接地技术研讨会论文集[C];2005年

9 陈健生;项昌富;黄显立;;电力接地网用导电防腐涂料[A];全国电网中性点接地方式与接地技术研讨会论文集[C];2005年

10 郑杰;;接地网技术在水口水电厂的综合应用[A];全国水电厂技术改造学习交流研讨会论文集[C];2005年

相关重要报纸文章 前8条

1 杨晓理 杨雁 段江;陕西接地网安全项目国际领先[N];中国电力报;2010年

2 通讯员 张书利 谭振武 吕金武;拜城电厂接地网防腐改造采用新技术[N];中国电力报;2005年

3 张小平;云南电网开展特高压接地网电阻测试[N];中国电力报;2008年

4 张劲;杆塔和接地网重污区腐蚀防治技术确保电网构建材料性能[N];中国电力报;2012年

5 李宣华 汪根萍;将乐百万资金构筑“防雷堡垒”[N];三明日报;2009年

6 刘树波;让设备远离雷击[N];中国水利报;2003年

7 蔡家友;确保迎峰度夏供电有保证[N];黔西南日报;2009年

8 本版编辑邋李彩琴 陈志群 何庆东 徐乐群 陶弘 周奎 宁建民 李彬;雨季三防 你准备好了吗?[N];中华合作时报;2008年

相关博士学位论文 前10条

1 郭卫;应用边界元法的复杂土壤中接地网性能研究[D];武汉大学;2013年

2 Aamir Qamar;基于磁场微分法的变电站接地网拓扑结构检测研究[D];重庆大学;2016年

3 张露;土壤参数反演和接地网优化问题研究[D];武汉大学;2014年

4 袁涛;接地网电气连接故障的诊断方法研究[D];重庆大学;2010年

5 鲁志伟;大型接地网工频接地参数的计算和测量[D];武汉大学;2004年

6 王树奇;基于分层约简模型的接地网腐蚀故障诊断研究[D];西安科技大学;2009年

7 赵志斌;复杂土壤中接地网性能分析与变电站内空间电磁场计算[D];华北电力大学(河北);2005年

8 倪云峰;接地网分块故障诊断及可及节点偏移影响的研究[D];西安科技大学;2010年

9 张蓬鹤;基于接地系统频域特性的接地网缺陷诊断研究[D];华中科技大学;2011年

10 吴茂林;变电站互感器宽频传输特性与接地网瞬态特性的研究[D];华北电力大学(河北);2004年

相关硕士学位论文 前10条

1 洪海涛;接地网状态综合检测分析方法及其实现[D];湖南大学;2009年

2 朱江;广深港客运专线接地测试及防雷方案研究[D];西南交通大学;2015年

3 罗勋;变电站接地网雷电冲击暂态特性研究[D];西南交通大学;2015年

4 傅浩峰;220kV甘露变接地网改造技术研究[D];华北电力大学;2015年

5 张航;风电场圆环接地网的冲击特性研究[D];长沙理工大学;2014年

6 黄胜鑫;接地网腐蚀诊断及腐蚀对接地网性能影响评估方法研究[D];重庆大学;2015年

7 林奔;基于建筑信息模型的电气特性计算仿真[D];浙江理工大学;2016年

8 袁源明;接地网断点的磁性源诊断方法研究[D];重庆大学;2015年

9 李炜;导电混凝土模块接地网优化设计研究[D];燕山大学;2016年

10 李亚欣;基于信号距离的变电站接地网故障诊断[D];西安科技大学;2015年



本文编号:1522989

资料下载
论文发表

本文链接:https://www.wllwen.com/kejilunwen/dianlidianqilunwen/1522989.html


Copyright(c)文论论文网All Rights Reserved | 网站地图 |

版权申明:资料由用户07d77***提供,本站仅收录摘要或目录,作者需要删除请E-mail邮箱bigeng88@qq.com