面向电力扰动数据分析的暂态扰动检测
发布时间:2018-03-11 19:18
本文选题:电力扰动 切入点:数据分析 出处:《电工技术学报》2017年03期 论文类型:期刊论文
【摘要】:面向电力扰动数据分析提出了一种暂态电力扰动检测方法。针对IEC推荐的暂态电能质量检测标准中波形对比法的缺陷,将改进型波形对比检测和有效值检测相结合,同时针对电压和电流数据进行检测,对暂态形式的电能质量及非电能质量扰动都具有较高的敏感性。通过应用于现场实测扰动数据表明,该方法能够有效检测出各类暂态电力扰动,较好的解决了检测灵敏度同所需数据量之间的矛盾,能够满足电力扰动数据分析对扰动检测的基本要求。
[Abstract]:A method of transient power disturbance detection is proposed for power disturbance data analysis. Aiming at the defect of waveform contrast method recommended by IEC, the improved waveform contrast detection is combined with RMS detection. At the same time, it is sensitive to transient power quality disturbance and non-power quality disturbance based on voltage and current data. This method can effectively detect all kinds of transient power disturbances and solve the contradiction between the detection sensitivity and the required data volume. It can meet the basic requirements of power disturbance data analysis for disturbance detection.
【作者单位】: 电网智能化调度与控制教育部重点实验室(山东大学);国网潍坊供电公司;国网智能电网研究院;国网济南供电公司;
【基金】:山东省重点科技计划(2015GGX104010) 山东省自然科学基金(ZR2013EEM026)资助项目
【分类号】:TM930
【参考文献】
相关期刊论文 前10条
1 李钷;张怡茹;;基于输入观测器理论的电流谐波检测方法[J];电工技术学报;2016年07期
2 曲朝阳;于华涛;郭晓利;;基于开启瞬时负荷特征的家电负荷识别[J];电工技术学报;2015年S1期
3 陈众励;许维胜;;电压中断与电压暂降的成因其及防治[J];电工技术学报;2015年S1期
4 龙虹毓;张晓勇;胡晓锐;冯姗姗;李龙;;蚁群优化小波阈值算法用于变电设备状态信号提取[J];电工技术学报;2015年12期
5 关维国;姚清志;高阳;鲁宝春;;基于db4小波的配电网暂态电能质量扰动的检测与定位[J];电力系统保护与控制;2015年08期
6 周国亮;朱永利;王桂兰;宋亚奇;;实时大数据处理技术在状态监测领域中的应用[J];电工技术学报;2014年S1期
7 李文江;范祖台;李f坛,
本文编号:1599537