褐煤机组烟气冷凝取水污染物减排特性
发布时间:2018-03-22 17:15
本文选题:褐煤机组 切入点:烟气冷凝取水 出处:《热力发电》2017年12期 论文类型:期刊论文
【摘要】:为研究褐煤机组烟气冷凝取水对各种污染物的减排效果,在某600 MW褐煤机组搭建了烟气冷凝取水试验系统。结果表明:随着冷却水入口温度的升高,烟气冷凝取水对SO_2的脱除效率从9.8%逐渐降至6.8%;随着换热器入口烟气中NH_4~+体积分数的增加,烟气冷凝取水对NH_4~+的脱除率逐渐上升,试验条件下NH_4~+脱除效率为19.7%~43.1%;颗粒物PM_(2.5)和PM_(10)的脱除效率随换热器入口冷却水温度的增加先升高后降低,而对PM_1的脱除效率则与之相反,试验条件下颗粒物PM_(2.5)的脱除效率在50%以内,尚有优化空间。
[Abstract]:In order to study the emission reduction effect of flue gas condensing water on various pollutants in a 600 MW lignite unit, a flue gas condensing test system was set up. The results show that with the increase of the inlet temperature of cooling water, The removal efficiency of SO_2 from flue gas condensate water gradually decreased from 9.8% to 6.8%, and the removal rate of NH4 ~ + from flue gas condensed water gradually increased with the increase of NH4 ~ + volume fraction in flue gas of heat exchanger inlet. Under the experimental conditions, the removal efficiency of NH _ 4 ~ ~ was 19.73.1and the removal efficiency of particulate matter (PMSP _ (2.5) and PMT _ (10)) increased first and then decreased with the increase of the temperature of the inlet cooling water of the heat exchanger, whereas the removal efficiency of PM_1 was less than 50% under the experimental condition. There is still room for optimization.
【作者单位】: 西安热工研究院有限公司;北方联合电力有限公司上都电厂;
【基金】:中国华能集团公司总部科技项目(HNKJ15-H11)~~
【分类号】:TM621
【相似文献】
相关期刊论文 前3条
1 邱朋华;李丹丹;徐宝龙;呼姚;杜昌帅;吴少华;;基于Aspen Plus对Selexol分离CO_2流程的分析[J];中国电机工程学报;2014年08期
2 吴成军;段钰锋;王运军;江贻满;王乾;杨立国;;410t/h煤粉锅炉的汞排放及其NID系统除汞特性研究[J];燃料化学学报;2008年05期
3 王运军;王宏伟;魏继平;高建康;郭晓民;;600MW超临界发电机组污染物脱除及排放[J];中国电力;2013年12期
相关硕士学位论文 前5条
1 孟镇;兼顾换热复合阳极用于静电除尘增效的试验研究[D];山东大学;2015年
2 魏巍;脉冲放电协同脱除烟气中多种污染物的研究[D];华北电力大学;2015年
3 蒋佳君;Ag(Ⅲ)配合物氧化烟气中Hg~0的实验研究[D];华北电力大学;2016年
4 徐昭然;干湿静电技术中蒸发对湿电场颗粒物脱除影响研究[D];山东大学;2017年
5 张明慧;烟气中超高浓度氮氧化物的前置氧化脱除机理研究[D];浙江大学;2015年