【摘要】:2016年末至2017年初,我公司对一台其他厂家生产的电厂用多级锅炉给水泵进行了检修。该泵主要故障为运行500小时后出现了断轴的问题,现场检修并更换主轴后振动仍然较大,运行不平稳。将该给水泵解体后发现密封环间隙超标,平衡盘、平衡座磨损严重,最主要的问题是现场新换的主轴已经弯曲变形。经研究决定重新测量检查、更换主轴,各叶轮密封环处加工成统一外径,重新加工配制密封环,在不更换叶轮的情况下实施有效的修复。对平衡盘、平衡座重新测绘加工处理,该给水泵经过处理修复后,运行状况良好,达到了预期效果。
[Abstract]:From the end of 2016 to the beginning of 2017, our company overhauled a multistage boiler feedwater pump in a power plant made by other manufacturers. The main failure of the pump is the failure of the shaft after 500 hours of operation. The vibration is still large and the operation is not stable after the maintenance and replacement of the main shaft. After disintegrating the feed pump, it is found that the clearance of the seal ring exceeds the standard, and the balance disc and the balance seat are worn seriously. The main problem is that the newly changed spindle has been bent and deformed. After study, it is decided to re-measure and check, to replace the spindle, to process each impeller seal ring into uniform outer diameter, to reprocess and prepare the seal ring, and to carry out effective repair without replacing impeller. After the reprocessing of the balance plate and the balance seat, the feed pump is in good operation condition and the expected effect is achieved.
【作者单位】: 沈阳市工业泵厂(有限公司);
【分类号】:TM621.2

【相似文献】

相关期刊论文 前4条

1 屈云亮;电机断轴再接[J];中小型电机;1998年03期

2 卢健翔;改进平衡盘以消除高压给水泵的故障[J];电力技术通讯;1975年04期

3 尹福伟;;DG100—59型给水泵平衡盘装置的改进[J];黑龙江电力技术;1986年04期

4 冯金泉;;DG270-140给水泵平衡盘事故原因分析[J];华东电力;1982年04期



本文编号:1887067

资料下载
论文发表

本文链接:https://www.wllwen.com/kejilunwen/dianlidianqilunwen/1887067.html


Copyright(c)文论论文网All Rights Reserved | 网站地图 |

版权申明:资料由用户3cea8***提供,本站仅收录摘要或目录,作者需要删除请E-mail邮箱bigeng88@qq.com