当前位置:主页 > 科技论文 > 电气论文 >

基于红外热像技术的电机定子线圈腐蚀诊断研究

发布时间:2018-07-03 05:50

  本文选题:红外热像 + 腐蚀 ; 参考:《腐蚀科学与防护技术》2017年06期


【摘要】:为了实现对电机定子线圈腐蚀缺陷的精确诊断,建立电机负载实验台,采用红外热像技术对三相异步电动机进行检测实验,获取不同工况下电机运行红外热像图,分析得到电机定子工作中的温度场数据及温度-频率曲线,通过分析数据,获取电机定子线圈因腐蚀导致的缺陷和绝缘性变化等损伤对应的红外特征及温度场变化规律。结果表明,通过对三相异步电动机定子线圈红外热像云图分析及验证,能够诊断电机定子线圈是否存在腐蚀及腐蚀位置。研究结果为电机定子线圈的故障诊断及预测提供了一种直接有效的新方法。
[Abstract]:In order to accurately diagnose the corrosion defects of motor stator coil, the motor load test bench was established, and the infrared thermal image was used to detect the three-phase asynchronous motor under different working conditions. The temperature field data and temperature-frequency curve of motor stator are obtained by analyzing the temperature field data, and the infrared characteristics and temperature field changes of stator coil damage caused by corrosion and insulation are obtained. The results show that the corrosion and corrosion position of stator coil can be diagnosed by analyzing and verifying the infrared thermal image of stator coil of three-phase asynchronous motor. The results provide a new direct and effective method for fault diagnosis and prediction of motor stator coil.
【作者单位】: 辽宁工程技术大学机械工程学院;四川理工学院材料腐蚀与防护四川省重点实验室;大连理工大学工业装备结构分析国家重点实验室;重庆大学机械传动国家重点实验室;徐州工程学院机电工程学院;
【基金】:国家自然科学基金(51504121) 教育部博士点基金(20132121120011) 材料腐蚀与防护四川省重点实验室开放基金(2014CL18) 工业装备结构分析重点实验室开放基金(GZ1402) 机械传动国家重点实验室开放基金(SKL MT-KFKT-201515)~~
【分类号】:TM307;TN219

【相似文献】

相关期刊论文 前10条

1 蔡庆永;定子线圈因接地击穿的不对称截除[J];电机技术;2002年04期

2 杨瀚;;定子线圈检查方法和检查记录的改进[J];东方电机;2007年06期

3 吴金英;;三峡发电机定子线圈热压模具设计[J];上海大中型电机;2009年02期

4 付世涛;黄勇;胡林;;发电机定子线圈、线圈出水温差大问题研究[J];电力技术;2009年06期

5 刘伟;;发电机定子线圈下沉分析、处理及防范措施[J];内蒙古水利;2010年03期

6 兰生平;马梅霞;李庆;;越南嘉兴水电厂发电机定子线圈损伤的修复[J];红水河;2012年02期

7 ;三十万千瓦双水内冷汽轮发电机定子线圈绝缘试制[J];大电机;1973年06期

8 ^儭,

本文编号:2092634


资料下载
论文发表

本文链接:https://www.wllwen.com/kejilunwen/dianlidianqilunwen/2092634.html


Copyright(c)文论论文网All Rights Reserved | 网站地图 |

版权申明:资料由用户26c55***提供,本站仅收录摘要或目录,作者需要删除请E-mail邮箱bigeng88@qq.com