核电厂乏燃料水池非能动喷淋冷却技术研究
发布时间:2018-01-04 10:51
本文关键词:核电厂乏燃料水池非能动喷淋冷却技术研究 出处:《华北电力大学》2015年硕士论文 论文类型:学位论文
【摘要】:日本福岛核电站事故发生后,乏燃料水池失去补水后的冷却问题引发了大家的关注。本实验设计了一套非能动乏燃料水池喷淋系统,并对其喷淋冷却效果进行了验证。实验用3×3棒束电加热棒模拟核电厂乏燃料水池中的一组乏燃料组件。本实验在冷态下对其喷淋后分析其喷淋流型,与单根棒的喷淋流行进行对比,在加热状态下分析喷淋冷却的冷却效果。探究不同喷淋流量与喷淋角度对乏燃料水池喷淋冷却效果的影响。
[Abstract]:After the accident of Fukushima nuclear power plant in Japan, the cooling problem of spent fuel pool after losing water has attracted much attention. In this experiment, a set of passive spent fuel pool spray system was designed. The effect of spray cooling was verified. A group of spent fuel assemblies in spent fuel pool of nuclear power plant were simulated with 3 脳 3 rod beam electric heating rod. The spray flow pattern was analyzed after spraying in cold state. The cooling effect of spray cooling was analyzed under heating condition, and the effect of different spray flow rate and spray angle on spray cooling effect of spent fuel tank was studied.
【学位授予单位】:华北电力大学
【学位级别】:硕士
【学位授予年份】:2015
【分类号】:TM623
【参考文献】
相关期刊论文 前2条
1 陈海英;刘圆圆;张春明;郭瑞萍;庄景齐;刘巧凤;;福岛乏燃料水池事故探讨[J];核安全;2012年02期
2 苏夏;;AP1000乏燃料池非能动冷却系统事故后冷却能力分析[J];中国核电;2013年02期