当前位置:主页 > 科技论文 > 电力论文 >

“下-上”和“上-下”高压电缆剩余寿命评估法在荷兰的应用(英文)

发布时间:2018-05-29 23:06

  本文选题:high-voltage + medium-voltage ; 参考:《高电压技术》2015年04期


【摘要】:Medium-voltage(MV)and high-voltage(HV)power cables constitute an important role for the continuous energy delivery to the customers.Despite a network redundancy,high reliability of the cable connections is necessary to maintain required network reliability.During the past period,the cable production technology has been a subject to a continuous change.For that reason,utilities around the world operate a number of cable types in their networks.Particularly,in the Netherlands,the distribution grid is constructed only with cables.Moreover,parts of the transmission grid also consist of HV power cables.The cable connections being in operation for a period of over 30 years suffered from different stresses during their service time.This continuous stressing results in gradual decrease of operational abilities and inevitable failure occurrence.In the period from 2008 to 2014,in the High-Voltage Group at TU Delft,several research projects on the reliability of MV and HV power cables of different types have been run.The current article contains a detailed review of the work that has been done.In each case,the problem description together with the applied methodologies and obtained results is presented.At the end of the paper,the suggestions for future researchers are made
[Abstract]:Medium-voltage(MV)and high-voltage(HV)power cables constitute an important role for the continuous energy delivery to the customers.Despite a network redundancy,high reliability of the cable connections is necessary to maintain required network reliability.During the past period,the cable production technology has been a subject to a continuous change.For that reason,utilities around the world operate a number of cable types in their networks.Particularly,in the Netherlands,the distribution grid is constructed only with cables.Moreover,parts of the transmission grid also consist of HV power cables.The cable connections being in operation for a period of over 30 years suffered from different stresses during their service time.This continuous stressing results in gradual decrease of operational abilities and inevitable failure occurrence.In the period from 2008 to 2014,in the High-Voltage Group at TU Delft,several research projects on the reliability of MV and HV power cables of different types have been run.The current article contains a detailed review of the work that has been done.In each case,the problem description together with the applied methodologies and obtained results is presented.At the end of the paper,the suggestions for future researchers are made
【作者单位】: DC
【分类号】:TM24

【相似文献】

相关期刊论文 前3条

1 ;On the direct use of recovered scrap copper and saving copper with aluminum in the Chinese cable industry[J];Engineering Sciences;2008年03期

2 ;Application Research Completed for a 75m HTS AC Power Cable[J];Bulletin of the Chinese Academy of Sciences;2006年03期

3 ;[J];;年期



本文编号:1952809

资料下载
论文发表

本文链接:https://www.wllwen.com/kejilunwen/dianlilw/1952809.html


Copyright(c)文论论文网All Rights Reserved | 网站地图 |

版权申明:资料由用户b0f2e***提供,本站仅收录摘要或目录,作者需要删除请E-mail邮箱bigeng88@qq.com