核电站保护系统信号交叉比较算法研究
[Abstract]:According to the change of actual operation parameters, the nuclear power plant protection system can prevent the reactor from exceeding the prescribed safety limit or reduce the consequences of the accident by controlling the reactor emergency shutdown and special safety facilities. According to the requirements of nuclear safety regulations, nuclear power plant protection system must be tested periodically to verify that its function and performance meet the design requirements of reliability. However, the current signal cross-comparison algorithm used in the T1 test of nuclear power plant protection system is insufficient, and the algorithm can not determine whether the redundant channel of the protection system exists "4-channel codirectional drift". Based on the detailed study of T1 test, this paper takes the signal cross-comparison algorithm of T1 test as the research object, discusses in detail the mathematical modeling and solving process of the algorithm, and puts forward an improved method on the original mathematical model. The improved algorithm realizes the judgment function of "4 channel codirectional drift", and has certain engineering value. The main results are as follows: (1) based on the mathematical model of the original signal cross-comparison algorithm, the shortcomings of this algorithm are proposed by reading a large number of relevant data from the T1 test of the nuclear power plant protection system. At the same time, the determination formulas of "setting datum channel" and "4-channel codirectional drift" are put forward to realize the improvement, and the program design of the improved algorithm is realized by using C#3.0 language. (2) based on the verification platform of Zhongguang Nuclear Design Institute, the implementation process of T1 test is designed. Real-time data acquisition is realized by PCTRAN software. At the same time, according to the precision criterion of nuclear safety important instrument, the standard deviation value in mathematical model is designed. (3) the T1 test is completed, and the data result is analyzed. The experimental results show that the improved algorithm not only meets the original function, but also can be used to judge the "four channels in the same direction", which is feasible.
【学位授予单位】:哈尔滨工程大学
【学位级别】:硕士
【学位授予年份】:2014
【分类号】:TM623
【参考文献】
相关期刊论文 前10条
1 冀焕青;;AP1000核电站数字化反应堆保护系统[J];自动化与仪表;2013年02期
2 杨汝贞;王五妹;;福清核电厂数字化保护系统定期试验方案及可行性分析[J];自动化博览;2012年08期
3 王振营;谢志国;郑文波;;红沿河核电站反应堆保护系统的DCS实现[J];中国高新技术企业;2011年05期
4 王巧燕;张黎明;李恒;;CPR1000新项目保护系统旁通功能设计[J];核科学与工程;2010年S1期
5 张龙强;江辉;田亚杰;;CPR1000新项目安全级仪控系统定期试验方案[J];核科学与工程;2010年S1期
6 罗传杰;文华;左新;;大亚湾核电站反应堆保护系统T1试验台的研制与应用[J];自动化博览;2010年09期
7 张冬冬;蒙海军;;红沿河核电站安全级DCS控制系统设计[J];电力建设;2009年06期
8 任春香;;田湾核电厂TXS系统模拟量输入信号交叉比较的设计分析[J];原子能科学技术;2008年11期
9 张东升;朱毅明;左新;;反应堆保护系统试验系统的研究[J];自动化博览;2008年05期
10 刘宏春;王涛涛;王华金;周继翔;刘光明;许东方;;岭澳二期核电站数字化反应堆保护系统[J];核动力工程;2008年01期
相关会议论文 前1条
1 陆炜伟;;在役核电站反应堆保护系统数字化改造项目安装和调试[A];中国核科学技术进展报告——中国核学会2009年学术年会论文集(第一卷·第3册)[C];2009年
相关博士学位论文 前1条
1 周海翔;核电厂数字化反应堆保护系统结构与可靠性研究[D];哈尔滨工程大学;2007年
相关硕士学位论文 前2条
1 张志飞;大亚湾核电站反应堆T1保护试验装置的国产化开发和应用[D];上海交通大学;2009年
2 叶明傲;压水堆核电厂主冷却剂集散控制系统技术研究[D];哈尔滨工程大学;2004年
,本文编号:2124572