接地对某型装备火控系统信号检测影响研究
发布时间:2018-02-15 22:52
本文关键词: 接地 信号检测 火控系统 共模干扰 浮地测量 出处:《微波学报》2014年S2期 论文类型:期刊论文
【摘要】:针对在某型装备检测维修过程中,对该装备火控系统的信号测量结果与实际值偏差较大的问题,分析了造成测量结果偏差的原因系检测装备与被测装备火控系统不同的接地方式导致在两接地点形成共模干扰电压,而检测装备中的测量仪器信号输入端输入电路不对称又将此共模干扰转化为差模干扰,从而造成测量结果与实际信号值偏差较大。通过在检测设备中采用浮地测量技术,较好的抑制了共模干扰电流,消除了信号检测误差。试验结果表明,该方案较好解决了因检测装备与被测装备不同接地方式造成信号测量偏差的问题。
[Abstract]:In view of the problem that the signal measurement results of the fire control system of a certain type of equipment deviate from the actual value in the course of inspection and maintenance of the equipment, It is analyzed that the reason for the deviation of measurement results is that the common mode interference voltage is formed at two connection points due to the different grounding modes between the testing equipment and the fire control system of the equipment under test. The asymmetric input circuit of the signal input of the measuring equipment converts the common-mode interference into the differential mode interference, which results in a large deviation between the measured results and the actual signal value. The common mode interference current is well suppressed and the signal detection error is eliminated. The experimental results show that the scheme can solve the problem of signal measurement deviation caused by different grounding modes between the tested equipment and the tested equipment.
【作者单位】: 北京特种机电技术研究所;南京军事代表局;
【分类号】:E92;TN911.23
【共引文献】
相关硕士学位论文 前8条
1 王强;基于正弦波励磁方法的电磁流量计电极间信号建模研究[D];哈尔滨理工大学;2011年
2 刘晶;微电子系统功耗估算与监测的仿真研究[D];苏州大学;2011年
3 张咏松;无人值守全台面动静态轨道衡系统研究[D];山东大学;2011年
4 彭镭;兆瓦级风力发电机监测与故障诊断系统设计[D];湖南大学;2010年
5 张晶晶;高精度电磁流量计的研制[D];中国计量学院;2012年
6 宋冰;汽车按键开关测试系统的开发[D];吉林大学;2013年
7 赵聘;晶体谐振器标刻工位的优化设计与研究[D];河北科技大学;2013年
8 王建坤;高速深侵彻过程测试关键技术的研究[D];中北大学;2015年
【二级参考文献】
相关硕士学位论文 前1条
1 苏艳茹;微小流量信号检测系统的研究及应用[D];哈尔滨工程大学;2005年
,本文编号:1514071
本文链接:https://www.wllwen.com/kejilunwen/wltx/1514071.html