环氧乙烷消毒麻醉机对COPD吸入麻醉患者气道炎症反应的影响

发布时间:2018-03-14 11:17

  本文选题:吸入性麻醉 切入点:气道炎症反应 出处:《中国医疗器械信息》2016年10期  论文类型:期刊论文


【摘要】:目的:探索不同麻醉机消毒方法对手术合并COPD吸入性麻醉患者气道炎症反应的影响。方法:有慢性阻塞性肺病(COPD)患者70例,随机均分为两组(n=35),观察组患者采用术前经环氧乙烷浸泡消毒的麻醉机进行麻醉;对照组患者则术前采用2%戊二醛溶液浸泡消毒麻醉机进行麻醉。检测两组插管后及插管后2h、4h血清及肺泡灌洗液中的TNF-α水平、IL-8、IL-2及IL-1β的浓度。结果:两组各血清因子浓度随时间延长而增加,插管后2h、4h各个指标浓度较刚插管后均显著增加(P均0.05)。两组肺泡灌洗液中各指标浓度随时间延长而增加,插管后2h、4h各个指标浓度较刚插管后均显著增加(P0.05)。IL-2浓度在各个时段观察组的浓度均显著低于对照组(P0.05)。TNF-α水平在插管后2h、4h时观察组浓度明显低于对照组,IL-8插管后2h时观察组浓度明显低于对照组,差异均有统计学意义(P0.05)。结论:COPD吸入性麻醉患者使用环氧乙烷消毒的麻醉机对气道炎症反应影响较小,环氧乙烷的消毒效果优于2%戊二醛溶液,对气道有一定的保护作用。
[Abstract]:Objective: to explore the effect of different anesthetic machine disinfection methods on airway inflammation in patients with COPD inhalation anesthesia. Methods: 70 patients with chronic obstructive pulmonary disease (COPD) were enrolled in this study. All the patients were randomly divided into two groups. The patients in the observation group were anesthetized with anaesthesia machine which was soaked and disinfected by ethylene oxide before operation. The patients in the control group were anesthetized with 2% glutaraldehyde solution immersion disinfectant anaesthesia machine before operation. The levels of TNF- 伪 and IL-8 IL-2 and IL-1 尾 in serum and alveolar lavage fluid were measured after intubation and 2 h after intubation. Results: each serum factor in both groups was determined. The concentration increases with time, Two hours after intubation, the concentration of each index was significantly higher than that after intubation (P < 0.05). The concentration of each index in alveolar lavage fluid of two groups increased with the prolongation of time. Two hours after intubation, the concentration of each index was significantly higher than that after intubation. The concentration of IL-2 in observation group was significantly lower than that in control group 2 hours after intubation. The concentration of TNF- 伪 in observation group was significantly lower than that in control group at 2 h after intubation and 2 h after intubation. The concentration of IL-2 in observation group was significantly lower than that in control group at 2 h after intubation. The concentration of observation group was significantly lower than that of control group. Conclusion the anesthetic machine disinfected by ethylene oxide has little effect on airway inflammation, and the disinfection effect of ethylene oxide is better than that of 2% glutaraldehyde solution, and it has a certain protective effect on airway.
【作者单位】: 辽阳市第二人民医院麻醉科;
【分类号】:R614

【参考文献】

相关期刊论文 前5条

1 王小玲;刘侃;;环氧乙烷消毒麻醉机对COPD吸入麻醉患者气道炎症反应的影响[J];河北医学;2015年10期

2 周学颖;赵峰;王萃;王莹莹;周乐;;两种麻醉机消毒方法效果比较[J];中华医院感染学杂志;2015年15期

3 张玮;万福红;梁宁;;不同干预方法对麻醉机通气系统病原微生物的影响[J];广西医学;2014年12期

4 吕红杰;董丽娟;吴亚辉;;麻醉机通气系统污染与全麻术后肺部感染的临床分析[J];中华医院感染学杂志;2014年18期

5 郭凯;黄美玲;崔绍敏;;麻醉机通气系统污染与患者全麻术后肺部感染的相关性研究[J];中华医院感染学杂志;2014年17期

【共引文献】

相关期刊论文 前6条

1 刘U,

本文编号:1610980


资料下载
论文发表

本文链接:https://www.wllwen.com/yixuelunwen/mazuiyixuelunwen/1610980.html


Copyright(c)文论论文网All Rights Reserved | 网站地图 |

版权申明:资料由用户eb446***提供,本站仅收录摘要或目录,作者需要删除请E-mail邮箱bigeng88@qq.com