尿液成分的近红外光谱分析原理及实现研究

发布时间:2018-02-01 05:38

  本文关键词: 尿液 近红外 虚拟分析仪 无试剂 出处:《重庆大学》2012年硕士论文 论文类型:学位论文


【摘要】:尿液检查是临床三大常规检查之一,其标本收集方便,尿液成分浓度的变化是反映泌尿生殖系统等人体代谢、脏器状态、病理变化的客观资料。然而,现行常用的借助生化化学方法的尿液分析,消耗大量试剂、费时费力、污染且价格昂贵。本文的目的在于利用目前活跃于分析化学领域中的近红外分析技术,构建一种快速、无试剂、无破坏的绿色尿液近红外检测分析系统。 论文在简述现行几种尿液检查方法的原理与应用的基础上,阐述了近红外分析技术的原理和物理化学基础等定量分析基本理论应用于尿液成分分析检测中的可行性,采用近红外透射技术,进行尿液近红外检测分析仪的系统硬软件研制探索。硬件系统的实现上详述了整个光学系统、电路系统和机械系统的总体结构设计和各功能模块的实现过程。软件系统的实现基于Visual C++6.0开发平台,利用软件技术和虚拟仪器技术构建尿液近红外检测分析仪的软件系统,,实现对检测数据的显示、分析、打印、存储等虚拟仪器各功能模块。 本研究用设计的系统样机进行了简单的测试实验,以验证系统的性能,为下一步实现完善的快速定量分析模型的建立奠定基础。 近红外分析测试条件灵活,其检测结果包含的信息也十分丰富,本系统研究要达到临床实用仪器精度仍需要进行大量试验来优化分析模型,论文结尾对研究工作进行了总结和展望。
[Abstract]:Urine examination is one of the three routine clinical examinations, its specimen collection is convenient, the change of urine component concentration is the objective data of human metabolism, organ state and pathological changes. The commonly used urine analysis by biochemical methods consumes a lot of reagents, which is time-consuming, laborious, polluting and expensive. The purpose of this paper is to utilize the near infrared analysis technology which is active in the analytical chemistry field at present. A fast, reagent-free and non-destructive near infrared detection system for green urine was constructed. On the basis of brief introduction of the principle and application of several existing methods of urine examination. The feasibility of applying the basic theory of quantitative analysis, such as the principle of near infrared analysis technology and physicochemical basis, to the analysis and detection of urine composition is described. The near infrared transmission technique is adopted. The hardware and software of the urine near infrared detection analyzer are explored. The whole optical system is described in detail on the realization of the hardware system. The overall structure design of the circuit system and the mechanical system and the realization process of each functional module. The realization of the software system is based on the Visual C 6.0 development platform. The software system of urine near infrared detection analyzer is constructed by using software technology and virtual instrument technology. The function modules of virtual instrument such as displaying, analyzing, printing, storing and so on are realized. In order to verify the performance of the system, a simple test experiment is carried out with the designed system prototype, which lays a foundation for the establishment of a perfect fast quantitative analysis model in the next step. Near-infrared analysis test conditions are flexible, the detection results are also very rich in information, this system to achieve the accuracy of clinical instruments still need a large number of experiments to optimize the analysis model. At the end of the thesis, the research work is summarized and prospected.
【学位授予单位】:重庆大学
【学位级别】:硕士
【学位授予年份】:2012
【分类号】:TH776

【参考文献】

相关期刊论文 前10条

1 王步青;王卫东;;虚拟仪器及其在生物医学工程中的应用[J];北京生物医学工程;2007年04期

2 王惠中;宿忠娥;默立峰;王芝华;;基于Delphi的尿液分析仪应用软件的研究与设计[J];电气自动化;2008年05期

3 钱国华 ,胡益斌 ,刘坚;全自动生化分析仪的设计[J];电子工程师;2002年08期

4 高荣强,范世福;现代近红外光谱分析技术的原理及应用[J];分析仪器;2002年03期

5 刘伟玲,张思祥,虞启琏,冉多钢,赵学玲;近红外光谱法用于尿液多成分分析[J];分析仪器;2004年01期

6 褚小立;王艳斌;陆婉珍;;近红外光谱仪国内外现状与展望[J];分析仪器;2007年04期

7 李健桢,汪仁煌,李貌,严仍友;智能马桶中近红外光尿液分析的方案探讨[J];广东工业大学学报;2005年03期

8 刘兴华;陈长缨;于志刚;王康模;;仪用LED光源均匀性及稳定性研究[J];光谱实验室;2009年01期

9 刘伟玲;张思祥;冉多钢;王建英;尹霞;关学强;;尿中葡萄糖含量的近红外光谱快速测量[J];光谱仪器与分析;2004年02期

10 胡继明,胡军;拉曼光谱在分析化学中的某些应用进展[J];光散射学报;1998年Z1期

相关博士学位论文 前2条

1 丁东;近红外光谱技术及其在生物医学中的应用研究[D];吉林大学;2004年

2 刘伟玲;多种光谱法检测尿液成分的理论与实验研究[D];天津大学;2006年

相关硕士学位论文 前2条

1 刘蓟;近红外光谱尿液分析仪的原理及实现[D];重庆大学;2011年

2 蔡永军;尿液检测的无试剂光谱法研究[D];天津大学;2004年



本文编号:1481075

资料下载
论文发表

本文链接:https://www.wllwen.com/yixuelunwen/swyx/1481075.html


Copyright(c)文论论文网All Rights Reserved | 网站地图 |

版权申明:资料由用户30c8f***提供,本站仅收录摘要或目录,作者需要删除请E-mail邮箱bigeng88@qq.com