基于脉搏色素光密度法的心输出量测量系统
发布时间:2018-11-11 09:52
【摘要】:临床上心输出量(CO)等心血管血流动力学参数是心脏功能状况及心血管疾病的诊断依据,传统CO检测方法操作繁杂、有创伤以及患者术后易引发并发症。针对此问题,研究了一种基于脉搏色素光密度法的心输出量测量系统,以朗伯比尔定律和色素稀释理论为基础,通过选取合适的双波长探测光源(805nm/940 nm)实现了动脉吲哚氰绿(ICG)色素浓度谱的无创实时测量,从ICG浓度稀释曲线中计算出CO的数值。将本系统测量的值与当前测量CO的金标准热稀释法的结果进行对比,平均误差为4.79%,相关系数为0.99。实验结果表明:本研究所设计的心输出量测量系统实现了CO的无创、准确测量,可为临床检测CO提供一种新的选择。
[Abstract]:Cardiovascular hemodynamic parameters such as cardiac output (CO) are the basis for the diagnosis of cardiac function and cardiovascular disease. Traditional CO detection methods are complicated and have trauma and complications after operation. In order to solve this problem, a heart output measurement system based on pulse pigment optical density method is studied, which is based on Lambert's law and pigment dilution theory. The non-invasive real-time measurement of the concentration spectrum of indocyanine green (ICG) pigment in arterial indocyanine green was realized by selecting suitable dual-wavelength detection light source (805nm/940 nm). The value of CO was calculated from the dilution curve of ICG concentration. The average error of the system is 4.79 and the correlation coefficient is 0.99, compared with the results obtained by the current gold standard thermal dilution method for CO measurement. The experimental results show that the cardiac output measurement system designed in this paper realizes the noninvasive and accurate measurement of CO, which provides a new choice for clinical detection of CO.
【作者单位】: 北华大学工程训练中心;北华大学电气信息工程学院;吉林大学仪器科学与电气工程学院;
【基金】:国家“十二五”科技支撑计划(2015BAI02B04) 吉林省发改委省级产业创新专项资金项目(2016C052-2) 吉林省教育厅“十二五”科学技术研究规划重点项目(440020031134);吉林省教育厅科学研究规划项目(JJKH20170034KJ,JJKH20170035KJ)
【分类号】:R318.6
本文编号:2324483
[Abstract]:Cardiovascular hemodynamic parameters such as cardiac output (CO) are the basis for the diagnosis of cardiac function and cardiovascular disease. Traditional CO detection methods are complicated and have trauma and complications after operation. In order to solve this problem, a heart output measurement system based on pulse pigment optical density method is studied, which is based on Lambert's law and pigment dilution theory. The non-invasive real-time measurement of the concentration spectrum of indocyanine green (ICG) pigment in arterial indocyanine green was realized by selecting suitable dual-wavelength detection light source (805nm/940 nm). The value of CO was calculated from the dilution curve of ICG concentration. The average error of the system is 4.79 and the correlation coefficient is 0.99, compared with the results obtained by the current gold standard thermal dilution method for CO measurement. The experimental results show that the cardiac output measurement system designed in this paper realizes the noninvasive and accurate measurement of CO, which provides a new choice for clinical detection of CO.
【作者单位】: 北华大学工程训练中心;北华大学电气信息工程学院;吉林大学仪器科学与电气工程学院;
【基金】:国家“十二五”科技支撑计划(2015BAI02B04) 吉林省发改委省级产业创新专项资金项目(2016C052-2) 吉林省教育厅“十二五”科学技术研究规划重点项目(440020031134);吉林省教育厅科学研究规划项目(JJKH20170034KJ,JJKH20170035KJ)
【分类号】:R318.6
【相似文献】
相关期刊论文 前10条
1 毛衣理;;心输出量计算机原理[J];上海生物医学工程通讯;1985年02期
2 ;心输出量测量仪[J];引进国外医药技术与设备;1995年03期
3 冯靖yN;经食道多普勒心输出量测定仪的临床应用及评述[J];医疗装备;1998年03期
4 杨东;刘妙芳;;临床床边患者心输出量检测技术原理分析及进展[J];中国医学装备;2005年12期
5 陆柳,李景锡;心率对每搏输出量和心输出量影响的讨论[J];中国医学物理学杂志;2002年04期
6 马维原;陈生;文宗曜;朝振山;王鸿儒;;红细胞聚集的电导法测量系统研制[J];医学物理;1991年Z1期
7 杨妹清;新型脑神经回路膜电位变化测量系统[J];光机电世界;1994年05期
8 陈和,黄智伟;无损伤血氧饱和度测量系统研究[J];南华大学学报(理工版);2002年02期
9 汤黎明 ,常本康 ,刘铁兵 ,吴敏;精密神经阈值测量系统研制[J];电子产品世界;2003年19期
10 魏丽君;;化学发光免疫分析仪测量系统的改进[J];光电子技术;2013年01期
相关会议论文 前1条
1 陈翔;谢振武;;心输出量的心导纳求积法微电脑自动分析[A];第二届全国心功能学术研讨会论文摘要汇编[C];1990年
相关硕士学位论文 前2条
1 宋学东;医用呼吸二氧化碳、笑气、氧气测量系统的研制[D];深圳大学;2016年
2 郑盛坤;基于顺磁特性的氧气浓度测量系统的研制[D];深圳大学;2017年
,本文编号:2324483
本文链接:https://www.wllwen.com/yixuelunwen/swyx/2324483.html