  本文选题:计算机软件 + 腕关节 ; 参考:《北京中医药大学》2012年硕士论文


【摘要】:目的:初步探讨计算机软件对桡骨远端X线影像测量的准确性和可行性。 方法:选取中国中医科学院望京医院放射科拍摄的标准腕关节数字化X线片30张,实验者本人用计算机腕关节测量软件进行相关测量;从上述X线片中随机选取1张,并从中国中医科学院望京医院骨科研究生中随机选取30名,此30名人员分别利用临床量尺测量方法及计算机腕关节测量软件测量的方法对上述1张X线片测量,每人每种方法测量一次。测量主要内容:桡骨尺偏角、尺骨变异、桡腕关节弧的弦长。 结果:计算机腕关节测量软件对桡骨纵轴的确定:远端取斜率点到桡腕关节面的距离为38.996±10.494mm,近端中点到桡腕关节面的距离为69.337±11.011mm;计算机腕关节测量软件测量数值的标准差、极差、离散系数等均较量尺测量的数值小;取测量值的离均差绝对值进行统计检验分析:尺偏角及桡腕关节弦长的P值小于0.05,具有统计学意义;尺骨变异的P值大于0.05,不具有统计学意义。 结论:不同人利用计算机腕关节测量软件进行测量的数值离散度较小,该软件具有较好的一致性及可重复性。
[Abstract]:Objective: to explore the accuracy and feasibility of computer software for radiographic measurement of distal radius. Methods: a total of 30 digital radiographs of wrist joint were taken by the Department of Radiology of Wangjing Hospital of Chinese Academy of traditional Chinese Medicine. Thirty graduate students of orthopedics in Wangjing Hospital of Chinese Academy of traditional Chinese Medicine were randomly selected. The 30 subjects were measured by the methods of clinical measurement and computer software measurement of wrist joint. Each method is measured once per person. Main content: radial ulnar deviation, ulnar variation, radial wrist arc chord length. Results: the distance between distal slope point and radiocarpal joint surface was 38.996 卤10.494mm and 69.337 卤11.011mm between the midpoint of proximal end and radiocarpal joint surface, and the standard deviation and extreme deviation of the value measured by computer wrist joint measurement software were obtained by using computer wrist joint measurement software to determine the longitudinal axis of radius: the distance from the distal slope to the radiocarpal joint was 38.996 卤10.494mm and 69.337 卤11.011mm, respectively. The difference between the measured values and the mean value was analyzed statistically: the P value of the ulnar deviation angle and the chord length of the radiocarpal joint was less than 0.05, which had statistical significance. The P value of ulnar variation was more than 0.05, which had no statistical significance. Conclusion: the numerical dispersion of wrist joint measurement software is small, and the software has good consistency and repeatability.
【学位授予单位】:北京中医药大学
【学位级别】:硕士
【学位授予年份】:2012
【分类号】:R816.8

【参考文献】

相关期刊论文 前10条

1 方琼;;数字化虚拟人体在医学中的应用进展(综述)[J];安徽卫生职业技术学院学报;2008年01期

2 刘延明,李敬安,李烨芳,高希彦;光学图象假彩色处理中的密度-颜色变换分析[J];大连理工大学学报;1988年03期

3 钟世镇;数字化虚拟人体的科学意义及应用前景[J];第一军医大学学报;2003年03期

4 周贤善;;医学图像处理技术综述[J];福建电脑;2009年01期

5 马卫华;三维图形重建及个体化人工髋关节研究进展及现状[J];骨与关节损伤杂志;2003年02期

6 李百川,张明;关节镜技术的历史与新进展[J];华夏医学;2003年04期

7 陈豪;汪方;王秋根;;骨盆骨折计算机辅助手术进展[J];国际骨科学杂志;2010年05期

8 刘荣;白刃;;计算机辅助骨折端旋转X线测量方法初探[J];创伤外科杂志;2007年02期

9 项世法,邓华秋,何向东;增强医学X光片衬比的数字图象处理方法[J];大连理工大学学报;1989年04期

10 邹才盛;方华盛;;CR与DR的临床应用研究及现状[J];河北医药;2010年06期



本文编号:2056080

资料下载
论文发表

本文链接:https://www.wllwen.com/yixuelunwen/yundongyixue/2056080.html


Copyright(c)文论论文网All Rights Reserved | 网站地图 |

版权申明:资料由用户f8b2f***提供,本站仅收录摘要或目录,作者需要删除请E-mail邮箱bigeng88@qq.com