某商品房现浇楼板裂缝检测与探讨
发布时间:2018-11-23 08:59
【摘要】:通过对出现裂缝的某商品房现浇楼板混凝土抗压强度、钢筋间距、板厚、钢筋保护层、裂缝宽度、长度的检测,得出裂缝产生的原因,提出出现裂缝的预防措施和修补方法。
[Abstract]:Through the examination of compressive strength, steel bar spacing, slab thickness, steel bar protective layer, crack width and length of cast-in-place floor concrete of a commercial building with cracks, the causes of cracks are obtained, and the preventive measures and repair methods for cracks are put forward.
【作者单位】: 安徽省宿州市建设工程质量检测中心;
【分类号】:TU755.7
,
本文编号:2350987
[Abstract]:Through the examination of compressive strength, steel bar spacing, slab thickness, steel bar protective layer, crack width and length of cast-in-place floor concrete of a commercial building with cracks, the causes of cracks are obtained, and the preventive measures and repair methods for cracks are put forward.
【作者单位】: 安徽省宿州市建设工程质量检测中心;
【分类号】:TU755.7
,
本文编号:2350987
本文链接:https://www.wllwen.com/guanlilunwen/chengjian/2350987.html