电磁换向阀铁芯管开裂故障分析
发布时间:2017-12-27 22:08
本文关键词:电磁换向阀铁芯管开裂故障分析 出处:《机床与液压》2017年16期 论文类型:期刊论文
【摘要】:针对某大型钢结构液压系统发生多起电磁换向阀铁芯管开裂故障,从阀件工作压力、服役环境和产品质量3个方面进行故障机制分析,通过平台动作过程中T口压力检测和铁芯管开裂特征材料失效分析,找出故障原因。结果表明:回油调速导致阀控箱内回油管实际压力大于阀件T口允许工作压力,并最终导致故障发生。
[Abstract]:For a large scale steel structure hydraulic system multi core solenoid valve pipe cracking fault, fault mechanism analysis from 3 aspects of the valve working pressure, service environment and product quality, failure analysis on the cracking characteristics of the material through the platform of action in the process of T pressure detection and core tube, find out the cause of the malfunction. The results show that the actual pressure of the return oil pipe in the valve control box is greater than that of the valve T port, which can lead to the failure of the valve.
【作者单位】: 航天发射场可靠性技术重点实验室;
【分类号】:TH137.52
【正文快照】: 电磁换向阀是液压系统中最常用的元件,安装在系统中实现油路的接通、断开或改变液压油的流动方向,以实现液压执行元件的启动、停止、改变运动方向和运动速度的目的[1-3]。在某航天发射场大型钢结构工作平台液压系统中,共列装了A型号电磁换向阀6个(同一批次),列装时间不到半年