【摘要】:基于核电站立式泵组的结构及安装特点,分析了其在现场频繁发生结构共振故障的原因及结构共振源的判断方法。结合核电站现场立式泵共振故障的分析与诊断方法,对立式泵组通过改变固有频率及现场动平衡来解决结构共振问题的思路与方法进行了研究,为此类转动设备的故障诊断提供了重要依据。
[Abstract]:Based on the structure and installation characteristics of the vertical pump set in nuclear power plant, the causes of frequent structural resonance faults and the method of judging the structural resonance source are analyzed.Combined with the analysis and diagnosis method of the resonance fault of the nuclear power station vertical pump, the train of thought and method of solving the structural resonance problem by changing the natural frequency and the field dynamic balance of the opposing pump group are studied.It provides an important basis for fault diagnosis of this kind of rotating equipment.