当前位置:主页 > 科技论文 > 电力论文 >

基于单相级联延时信号消除法的三相基波正序有功电流检测方法

发布时间:2018-01-20 12:07

  本文关键词: 电能质量 基波正序有功电流 扇合矢量变换 级联延时信号消除 出处:《电网技术》2014年08期  论文类型:期刊论文


【摘要】:快速准确地检测基波正序有功电流,对电能质量控制非常重要。许多传统方法都需使用锁相环、低通滤波器或进行??和dq坐标变换。为此,提出了一种新型检测方法。首先通过扇合矢量变换,将三相系统的电压和电流归一化为单相系统;然后通过构造级联延时信号消除模块对基波正序电压和电流进行快速提取;最后通过简单的数学计算,得到基波正序有功电流。该方法既不需要锁相环,也不需要低通滤波器,还能够省略使用??和dq坐标变换时的复杂计算。仿真结果验证了所提方法的有效性。
[Abstract]:Fast and accurate detection of the fundamental positive sequence active current is very important for power quality control. Many traditional methods need to use phase-locked loop, low-pass filter or carry out? ? In this paper, a new detection method is proposed. Firstly, the voltage and current of the three-phase system are normalized to single-phase system by fan vector transformation. Then, the forward sequence voltage and current of the fundamental wave are extracted quickly by constructing the concatenated delay signal cancellation module. Finally, through simple mathematical calculation, the positive sequence active current of the fundamental wave is obtained. This method does not need a phase-locked loop or a low-pass filter, and can be omitted. ? The simulation results show that the proposed method is effective.
【作者单位】: 哈尔滨工业大学电气工程及自动化学院;
【基金】:国家自然科学基金重点项目(51237002)~~
【分类号】:TM933.1
【正文快照】: 0引言随着电力电子技术的迅速发展,非线性冲击性负载在电力系统中使用日益广泛,所产生的无功电流、负序电流和谐波电流对电力系统稳定运行造成严重影响。使用电能质量控制装置快速地进行无功补偿和有源滤波,对提高电力系统的稳定性具有重要的现实意义[1-3]。因此,如何快速准确

【相似文献】

相关期刊论文 前2条

1 粟时平;郑龙;吕振梅;罗嘉文;;一种基于三相电压畸变的p-q电流检测法[J];长沙理工大学学报(自然科学版);2008年01期

2 王玉斌;吕燕;李英俊;;三相电压不对称时谐波和无功电流的准确检测新方法[J];继电器;2006年18期

相关硕士学位论文 前1条

1 李育宁;通用并网变换器同步锁相环的研究[D];西安理工大学;2008年



本文编号:1448131