超临界W型火焰锅炉垂直水冷壁水动力特性研究
本文关键词: 内螺纹管 水动力特性 流量偏差 热负荷偏差 垂直水冷壁 出处:《锅炉技术》2016年01期 论文类型:期刊论文
【摘要】:对超临界W型火焰锅炉垂直水冷壁的水动力特性进行研究,首先对锅炉应用的材料为SA-213T12的ф31.8mm×5.5mm四头优化内螺纹管在试验台进行阻力特性研究,得到摩擦阻力系数λ。根据摩擦阻力系数λ及运行参数,计算某电厂600 MW超临界机组直流锅炉炉膛垂直水冷壁的阻力特性、流量偏差及热负荷偏差,并对水冷壁的水动力特性进行分析研究。
[Abstract]:The hydrodynamic characteristics of vertical water wall of supercritical W-type flame boiler are studied. First of all, the resistance characteristics of four-end optimized internal threaded tube with SA-213T12 is studied on the test bench. According to the friction resistance coefficient 位 and operation parameters, the resistance characteristics, flow deviation and heat load deviation of the furnace vertical water wall of a 600 MW supercritical unit once-through boiler in a power plant are calculated. The hydrodynamic characteristics of water wall are analyzed and studied.
【作者单位】: 贵州电网有限责任公司;贵州华电桐梓发电有限公司;上海望特能源科技有限公司;
【基金】:中国南方电网公司科技项目(k-GZ2012-123)
【分类号】:TK221
【正文快照】: 用内螺纹垂直管圈,出口每4根有一壁温测点,0 前 言标高44.915m,四面墙共434个壁温测点,前后 目前超(超)临界发电机组逐渐成为我国电墙各167个,左右侧各50个。上水冷壁测点较力生产的主力机组,随着超(超)临界机组的大规少,标高64.7m,共92个温度测点,前墙58个,模应用,超临
【相似文献】
相关期刊论文 前10条
1 张习强,曾汉才;W型火焰锅炉双调风旋流燃烧器特性分析[J];湖北电力;2003年04期
2 车刚 ,郝卫东 ,郭玉泉;W型火焰锅炉及其应用现状[J];电站系统工程;2004年01期
3 易洪波;W型火焰锅炉性能研究[J];湖北电力;2005年04期
4 陈天熙;;国内W型火焰锅炉的探讨[J];中小企业管理与科技(下旬刊);2009年08期
5 陈利飞;;600MW超临界W型火焰锅炉主要技术特点[J];机械工程师;2011年06期
6 王东明;刘曼立;;W型火焰锅炉概述及前景分析[J];锅炉制造;2011年04期
7 周刚;华能珞璜电厂W型火焰锅炉的特点分析[J];能源研究与信息;2001年04期
8 陈华;W型火焰锅炉燃烧技术探索[J];湖北电力;2002年06期
9 张杰,余战英,谭厚章,徐通模,惠世恩;W型火焰锅炉的热态试验研究[J];动力工程;2003年05期
10 王海;宋绍伟;;W型火焰锅炉节油技术集成应用[J];节能技术;2012年06期
相关硕士学位论文 前5条
1 田德建;巴威W型火焰锅炉配风优化方案及试验[D];昆明理工大学;2015年
2 车丹;W型火焰锅炉燃烧特性的研究[D];太原理工大学;2006年
3 汪飞;基于燃烧监测的W型火焰锅炉简化模型及燃烧优化[D];华中科技大学;2011年
4 孙亮;二次风射流角度对W型火焰锅炉炉内气固流动的影响[D];哈尔滨工业大学;2008年
5 秦占峰;600MW燃煤机组W型火焰锅炉优化吹灰试验与工程实现[D];华北电力大学(河北);2006年
,本文编号:1481609
本文链接:https://www.wllwen.com/kejilunwen/dongligc/1481609.html