离子色谱法测定碳酸锂中氯离子和硫酸根离子的含量
发布时间:2018-07-24 14:09
【摘要】:取碳酸锂样品0.500g,加适量水溶解,用水定容至100mL。分取试液10.00mL在不去除碳酸根基体的前提下直接进行离子色谱分析。采用阴离子交换柱Dionex IonPac AS11作为分离柱,用氢氧化钾淋洗液发生器产生的15mmol·L~(-1) KOH溶液为流动相,流量为1.0mL·min~(-1),柱温为30℃进行色谱分离和测定。氯离子和硫酸根离子的线性范围分别在16.0mg·L~(-1)和3.2mg·L~(-1)以内,检出限(3s/k)分别为0.004,0.01mg·L~(-1)。对同一个样品进行精密度试验,测定值的相对标准偏差(n=6)小于2.7%。按标准加入法进行回收试验,回收率在93.8%~106%之间。分析结果表明,样品测定结果与电化学法和在线去除基体离子色谱法的测定结果相符。
[Abstract]:The lithium carbonate sample 0.500g was dissolved with water, and the liquid was fixed to 100mL. to separate the liquid 10.00mL on the basis of no carbon acid base. The anion exchange column Dionex IonPac AS11 was used as the separation column and the produced 15mmol. L~ (-1) KOH solution produced by the potassium hydroxide leaching solution was the mobile phase. The chromatographic separation and determination of 1.0mL. Min~ (-1) and column temperature at 30 C. The linear range of chloride and sulfate radical ions is within 16.0mg. L~ (-1) and 3.2mg. L~ (-1) respectively. The detection limit (3s/k) is 0.004,0.01mg L~ (3s/k). The precision test of the same sample is carried out. The relative standard deviation of the measured value is less than the standard addition method The recovery test was carried out and the recovery rate was between 93.8%~106%. The results of the analysis showed that the results of the samples were in agreement with the results of the electrochemical method and the on-line removal of the matrix ion chromatography.
【作者单位】: 中国科学院上海硅酸盐研究所;
【基金】:上海市无机非金属材料分析测试表征专业技术服务平台资助(14DZ2292900)
【分类号】:TQ131.11;O657.7
本文编号:2141619
[Abstract]:The lithium carbonate sample 0.500g was dissolved with water, and the liquid was fixed to 100mL. to separate the liquid 10.00mL on the basis of no carbon acid base. The anion exchange column Dionex IonPac AS11 was used as the separation column and the produced 15mmol. L~ (-1) KOH solution produced by the potassium hydroxide leaching solution was the mobile phase. The chromatographic separation and determination of 1.0mL. Min~ (-1) and column temperature at 30 C. The linear range of chloride and sulfate radical ions is within 16.0mg. L~ (-1) and 3.2mg. L~ (-1) respectively. The detection limit (3s/k) is 0.004,0.01mg L~ (3s/k). The precision test of the same sample is carried out. The relative standard deviation of the measured value is less than the standard addition method The recovery test was carried out and the recovery rate was between 93.8%~106%. The results of the analysis showed that the results of the samples were in agreement with the results of the electrochemical method and the on-line removal of the matrix ion chromatography.
【作者单位】: 中国科学院上海硅酸盐研究所;
【基金】:上海市无机非金属材料分析测试表征专业技术服务平台资助(14DZ2292900)
【分类号】:TQ131.11;O657.7
【相似文献】
相关期刊论文 前10条
1 周凤文;高永勤;任庆海;;钡电极试样加入减量法测定毛皮鞣液中的硫酸根离子[J];陕西科技大学学报;1988年02期
2 闫立荣;分光光度法直接测定硫酸根离子[J];国外医学(卫生学分册);1989年06期
3 闫美兰,车吉泰,章咏华,孙家珍;功能高分子活性材料硫酸根离子选择电极的研制[J];功能高分子学报;1991年01期
4 李广;;硫酸根离子的快速测定[J];韶关大学学报(自然科学版);1993年02期
5 胡广军,严季新;铝箔腐蚀液中硫酸根离子的测定[J];电子元件与材料;1996年04期
6 范世华,方肇伦;环境水中微量硫酸根离子的流动注射分光光度法测定[J];光谱学与光谱分析;1998年05期
7 iJ辰;;答读者问[J];铀矿地质;1964年06期
8 李莲蓉;牟艳春;王大峰;;络合滴定法测定硫酸根离子的方法改进[J];科技创新导报;2012年23期
9 冯瑞;;混合溶液中硫酸根离子浓度测定方法的改进[J];化工技术与开发;2014年08期
10 金盈;方臻;吴友吉;;偕胺肟合汞(Ⅱ)纤维对硫酸根离子吸附性能的研究[J];安徽师范大学学报(自然科学版);2010年02期
相关硕士学位论文 前1条
1 卢磊;大孔大比表面积薄水铝石的制备及其在催化裂化中的应用[D];北京化工大学;2016年
,本文编号:2141619
本文链接:https://www.wllwen.com/kejilunwen/huagong/2141619.html