合流制管网污水溢流污染特征及其控制技术研究
[Abstract]:In this study, the combined pipe network in Changzhou, southern Jiangsu province, was sampled and analyzed in the rainy days and its related daily sewage, runoff Rain Water and pipeline sediment, etc. The characteristics of wastewater quality and pollution load operation of combined flow (CSO) for sewage overflow are discussed. The suspended fast filter for rapid treatment of CSO at the end of pipe network is designed. The monitoring and analysis of the water quality of the combined sewage overflow shows that the pollutant concentration in the effluents is high and varies greatly. In the monitored overflow events, the EMC values of the COD,TN,TP,NH3-N and SS concentrations are 33 ~ 649 mg / L ~ (60) mg 路L ~ (-1) and 30 mg 路L ~ (-1), respectively. 0.182.09mg / L 322mg / L and 23336mg / L, the water quality is inferior to the class V water quality standard (GB 3838-2002). The effects of rainfall types on pollutants in overflow sewage are different. The effects of heavy rainfall on COD and SS are significant, and the characteristics of water quality show obvious polarization, while the influence of small intensity rainfall on NH3-N is more obvious. The moderate intensity rainfall is continuously affected by the scour effect, which causes the pollutant concentration to be in the middle or higher level. The flood water quality will also be affected during the drought period, and the pollution will be serious during the long drought period due to the accumulation of pollutants. According to the analysis of the pollution load in the combined flow pipeline, the sediment in the pipeline is the most important pollutant source in CSO, and the contribution to COD,TN,TP,NH3-N,SS is about 53% and the proportion of the contribution to the COD,TN,TP,NH3-N,SS is about 53%, 68%, 43%, 56%, 42%, and 62%, respectively. 23 / 46% and 57 / 67; Second was Rain Water, who contributed 17% of the total amount of runoff, and 33% of the total amount of water, including 10%, 10% and 26% of the total, including 1130%, 18% and 36% of the total. The daily sewage is relatively small, and the contribution ratio is 9, respectively. The contribution ratio of different pollution sources is affected by rainfall intensity. The contribution ratio of different underlying surfaces in runoff Rain Water is also different. Road runoff is the main source of runoff pollutants, roof is the second, courtyard is the smallest. The critical rainfall intensity of the pump station can be obtained by converting the capacity of intercepting pollution into the equivalent of rainfall intensity and considering the multiple of closure, which can be used to judge whether the pumping station overflows in a single rainfall. The analysis of MV curve of overflow sewage shows that the combined flow system exhibits different scour phenomena under different rainfall intensity, and no scour effect in small intensity, medium intensity and large intensity rainfall events. Initial scour effect and intermediate scour effect. In this paper, a suspension fast filtration device for CSO terminal treatment is designed. The device is mainly used to remove SS and related pollutants from wastewater by physical interception and adsorption. The experimental results show that the average removal rate of SS can reach more than 45% at high filtration rate. The results show that when the particle size exceeds 90 渭 m, the removal rate can reach more than 50%, and when the particle size exceeds 150 渭 m, the removal efficiency can reach 100%.
【学位授予单位】:清华大学
【学位级别】:硕士
【学位授予年份】:2015
【分类号】:X703
【相似文献】
相关期刊论文 前10条
1 吴春笃;张贝贝;任雁;张波;;镇江市合流制管网溢流污染源解析[J];环境科学与技术;2011年10期
2 唐磊;车伍;赵杨;;基于低影响开发的合流制溢流污染控制策略研究[J];给水排水;2013年08期
3 唐磊;车伍;赵杨;宫永伟;;合流制溢流污染控制系统决策[J];给水排水;2012年07期
4 邢丽贞;王恩革;常青霞;;合流制污水溢流治理技术综述[J];山东建筑大学学报;2011年02期
5 何庆慈,李立青,孔玲莉,尹澄清;武汉市汉阳区的暴雨径流污染特征[J];中国给水排水;2005年02期
6 侯帅华;贾宝秋;;老城区排水系统改造新模式[J];重庆科技学院学报(自然科学版);2008年02期
7 鹿海峰;华蕾;王浩正;栾晓佳;陈维;;城市合流制管网降雨径流污染特征分析[J];中国环境监测;2012年06期
8 陈本劭;;合流制污水系统拍门利用液压锁扣装置控制启闭的研究[J];中华民居(下旬刊);2013年11期
9 李田;戴梅红;张伟;钱立鹏;;水泵强制排水系统合流制溢流的污染源解析[J];同济大学学报(自然科学版);2013年10期
10 陈威;徐明明;;河道内合流制截污干管的设计[J];工程建设;2012年03期
相关会议论文 前3条
1 杨根权;;浅谈旧合流制排水管渠系统的改造[A];第四届全国给水排水青年学术年会论文集[C];2000年
2 冯生华;;新建地区的排水系统应因地制宜采用分流制或合流制[A];中国土木工程学会水工业分会第四届理事会第一次会议论文集[C];2002年
3 张先立;刘杏;;采用薄壁孔口控制污水截流井设计流量[A];西南六省、区、市七方土木建筑工程学会第二十四次学术年会论文集[C];2006年
相关重要报纸文章 前2条
1 ;深隧建设或可破解内涝难题[N];建筑时报;2013年
2 姬跃国 王召东 尹卫红(作者单位:河南省城乡规划设计研究院);加强雨水处理十分必要[N];中国建设报;2002年
相关博士学位论文 前1条
1 陈勇民;承压式合流制溢流深井淤积及清淤技术研究[D];浙江大学;2011年
相关硕士学位论文 前8条
1 李思远;合流制管网污水溢流污染特征及其控制技术研究[D];清华大学;2015年
2 唐磊;合流制改造及溢流污染控制技术与策略研究[D];北京建筑大学;2013年
3 耿立馨;合流制管道沉积物冲刷模型试验研究[D];武汉理工大学;2013年
4 潘科;改良式合流制在中小城镇的应用研究[D];西南交通大学;2005年
5 崔爽;合流制管道沉积物中氮和有机物污染特性研究[D];北京建筑大学;2014年
6 徐一茗;基于SWMM的巢湖市老城区合流制管道溢流污染的模拟研究[D];安徽建筑工业学院;2011年
7 高潮;SD模型在合流制排水管网溢流污染控制中的应用研究[D];西南交通大学;2014年
8 郭海泉;西安市截流干管水质水量变化规律与解析[D];西安建筑科技大学;2014年
,本文编号:2406367
本文链接:https://www.wllwen.com/kejilunwen/huanjinggongchenglunwen/2406367.html