微分脉冲阳极溶出伏安法测定水处理剂用铝酸钙中砷
本文关键词: 微分脉冲 阳极溶出伏安法 水处理剂用铝酸钙 砷 出处:《冶金分析》2017年12期 论文类型:期刊论文
【摘要】:采用活性面位于侧面的金电极作为工作电极,建立了微分脉冲阳极溶出伏安法测定水处理剂用铝酸钙中砷含量的检测方法。将水处理剂用铝酸钙粉用氯化铝溶液加热回流溶解,经过滤后,对滤液进行稀释,以18%(质量分数)盐酸为支持电解质,对样品稀释液进行微分脉冲扫描阳极溶出伏安法测定。结果表明,砷在金电极上于峰电位为+0.09V左右产生灵敏的溶出峰,该峰峰高与砷的质量浓度在0.5~10μg/L之间呈现良好的线性关系,相关系数为0.997 7,检出限为0.15μg/L。按照实验方法对水处理剂用铝酸钙样品进行测定,并采用电感耦合等离子体质谱法(ICP-MS)做方法对照,同时加入砷标准溶液进行加标回收试验,结果表明,两种方法的测定结果基本一致,且实验方法的加标回收率为90%~102%。对3个水处理剂用铝酸钙样品测定结果的相对标准偏差(RSD,n=6)为2.1%~3.3%。
[Abstract]:A method for the determination of arsenic in calcium aluminate used as water treatment agent by differential pulse anodic stripping voltammetry was established by using the gold electrode on the side of the active surface as the working electrode. The water treatment agent was heated with calcium aluminate powder and dissolved by reflux with aluminum chloride solution. After filtration, the filtrate was diluted and 18% hydrochloric acid was used as the supporting electrolyte. The sample dilution was determined by differential pulse scanning anodic stripping voltammetry. The peak potential of arsenic at the gold electrode is about 0.09V, and the peak height has a good linear relationship with the mass concentration of arsenic in the range of 0.5 ~ 10 渭 g 路L ~ (-1) 路L ~ (-1). The correlation coefficient is 0.997 7, the detection limit is 0.15 渭 g / L. the sample of calcium aluminate used in water treatment agent is determined according to the experimental method, and the ICP-MS method is used as the control method, and the standard solution of arsenic is added to the standard solution to carry out the standard recovery test. The results showed that the results of the two methods were basically the same, and the standard recovery of the two methods was 90 and 102, and the relative standard deviation for the determination of calcium aluminate samples for the three water treatment agents was 2.1% and 3.3% respectively.
【作者单位】: 河南省科学院高新技术研究中心;
【基金】:中央高校基本科研业务费专项资金资助
【分类号】:O657.1;TQ085.412
【相似文献】
相关期刊论文 前10条
1 樊正;张荣;;水处理剂聚合硫酸铁中六价铬的检测方法探讨[J];中国卫生检验杂志;2010年06期
2 郑恩,喻海雅,谢晖;石墨炉原子吸收光谱法测定水处理剂中微量铅和镉[J];光谱学与光谱分析;2000年03期
3 张永清;;聚合FeCl_3水处理剂的作用机理及应用[J];衡阳师专学报(自然科学);1990年06期
4 罗旭东;曲殿利;谢志鹏;遇龙;;La_2O_3对反应烧结制备六铝酸钙结构性能的影响[J];人工晶体学报;2013年12期
5 罗玉长;;铝酸钙水泥中游离态Al_2O_3特性的研究[J];轻金属;1988年06期
6 谢文,宋远志,王柏;饮用水中铅的方波阳极溶出伏安法测定[J];中国公共卫生;2005年11期
7 方禹之;金利通;;阳极溶出伏安法测定光谱纯硒中痕量的铜[J];华东师范大学学报(自然科学版);1978年01期
8 施清照 ,陶天鹰 ,梁仲文 ,吕荣山;阳极溶出伏安法同时测定血清中的铅、镉[J];杭州大学学报(自然科学版);1982年04期
9 高劏,孙长清,顾梅英,杨骥;阳极溶出伏安法测定土壤中的银[J];吉林大学自然科学学报;1983年04期
10 周漱萍;王永辉;张祥民;王小宝;;阳极溶出伏安法测定高纯金属铟中痕量铋[J];新乡师范学院学报(自然科学版);1984年02期
相关会议论文 前2条
1 张名楠;刘斌;周政;徐金瑞;;阳极溶出伏安法测定三苯基锡的应用研究[A];全国第八届有色金属化学与电化学分析、第六届有色金属色谱分析、第四届有色金属物理检测、首届有色金属质谱分析学术交流会、全国第九届轻金属分析学术会议论文选编论文集[C];2004年
2 鞠q,
本文编号:1508609
本文链接:https://www.wllwen.com/kejilunwen/huaxuehuagong/1508609.html