当前位置:主页 > 科技论文 > 金属论文 >

埋地钢质管道强制电流阴极联合保护研究

发布时间:2019-06-07 20:42
【摘要】:目的验证阴极保护系统在保护目标管道的同时对临近管道造成的杂散电流腐蚀,对比柔性阳极与阳极地床在保护管道的过程中产生的杂散电流污染情况,确定同沟铺设的不同管道联合保护方案。方法通过同一排流设备对相同区域的不同管线进行统一保护,阴极保护系统中的接地装置作为唯一的阳极,多条埋地管线作为电化学电池的阴极实现保护。结果阳极地床产生的杂散电流干扰明显强于柔性阳极材料;排流保护中,两条20 m埋地金属管道达到排流保护的范围时,柔性阳极的排流电压为1.2~1.52 V,远小于碳钢阳极地床的3.5~15 V,能够有效减少防护过程中电能的使用。结论同一阴极系统同时对多条金属管道或金属构筑物进行排流保护的措施可行。
[Abstract]:Objective to verify the stray current corrosion caused by cathodic protection system while protecting the target pipeline, and to compare the stray current pollution caused by flexible anode and anode ground bed in the process of protecting pipeline. Determine the joint protection scheme of different pipelines laid in the same ditch. Methods different pipelines in the same area were protected by the same drainage equipment. The grounding device in the cathodic protection system was used as the unique anode, and several buried pipelines were used as the cathodic protection of electrochemical batteries. Results the stray current interference caused by anode ground bed was obviously stronger than that of flexible anode material. In discharge protection, when two 20 m buried metal pipes reach the range of drainage protection, the discharge voltage of flexible anode is 1.2 鈮,

本文编号:2495073

资料下载
论文发表

本文链接:https://www.wllwen.com/kejilunwen/jinshugongy/2495073.html


Copyright(c)文论论文网All Rights Reserved | 网站地图 |

版权申明:资料由用户37b96***提供,本站仅收录摘要或目录,作者需要删除请E-mail邮箱bigeng88@qq.com