自校准光谱辐射计信号采集及系统控制设计
本文关键词:自校准光谱辐射计信号采集及系统控制设计 出处:《中国科学技术大学》2017年硕士论文 论文类型:学位论文
更多相关文章: 自发参量下转换 自校准 符合测量 高速数据采集 LabVIEW
【摘要】:针对传统辐射定标精度已不能满足定量应用和气候变化研究的迫切需求,课题组计划研制一种基于自发参量下转换,具有自校准和辐射观测两种工作模式的光谱辐射计。本文主要解决该辐射计自动化定标及采集软件精度验证方面的问题。根据测量需求设计了自校准辐射计数据采集系统控制方案,基于LabVIEW语言编写了自校准辐射计数据采集系统控制软件。自校准模式能够自动定标多个通道探测效率,观测模式能够同时获得多个通道μs间隔的光子计数。自校准模式时,利用355nm激光泵浦BBO晶体,使用编写的自校准模式软件定标了APD在736nm波长点的量子效率为67.3%,测量的不确定度优于0.71%,和APD出厂数据的相对偏差为1%;观测模式时,使用编写的软件采集0.1s时间内APD输出计数值,并和994计数器输出值比较,平均相对偏差为0.22%,可以证明编写的控制软件能够满足系统的功能要求。设计了辐射计自校准原理有效性验证实验方案,基于LabVIEW语言编写了对应的控制软件。通过向光路中插入不同倍率的衰减片来模拟系统的衰变,选择积分球出射的单色均匀光作为观测光源,利用编写的控制软件测量不同衰减对应的入瞳相对光谱辐亮度,相对偏差为2.39%,证明设计的自校准辐射计反演的光谱辐亮度不随系统的衰变而发生变化,系统具有自校准功能。研制的自校准光谱辐射计的最终目标是作为可见~近红外波段空间光学遥感器的辐射基准,对其它光学遥感器进行定标。因此论文最后分析了当前数据采集系统的精度限制和体积限制,提出了一种基于时间数字转换(TDC)的高精度和小型化的数据采集系统设计方案。
[Abstract]:In view of the traditional radiometric calibration accuracy can no longer meet the urgent needs of quantitative applications and climate change research, the team plans to develop a kind of down-conversion based on spontaneous parameters. Spectral radiometer with two working modes of self calibration and radiation observation. This paper mainly solves the problems of automatic calibration of radiometer and precision verification of acquisition software. According to the requirement of measurement, the data of self calibration radiometer is designed. Control scheme of acquisition system. The control software of data acquisition system of self-calibrating radiometer is programmed based on LabVIEW language. The self-calibration mode can automatically calibrate the detection efficiency of multiple channels. In the self-calibrating mode, the BBO crystal is pumped by 355nm laser at the same time. The self-calibration mode software is used to calibrate the quantum efficiency of APD at 736nm wavelength, and the uncertainty of measurement is better than 0.71%. And the relative deviation of APD data is 1. In the observation mode, the APD output count value is collected in 0.1 s by using the software, and the average relative deviation is 0.22% compared with the output value of the 994 counter. It can be proved that the control software can meet the functional requirements of the system. An experimental scheme to verify the validity of the radiometer self-calibration principle is designed. The corresponding control software is compiled based on LabVIEW language. The decay of the system is simulated by inserting attenuation slices of different rates into the optical path, and the monochromatic uniform light emitted from the integral sphere is selected as the observation light source. The relative spectral radiance of different attenuation was measured with the control software, and the relative deviation was 2.39%. It is proved that the spectral radiance of the self-calibrated radiometer does not change with the decay of the system. The system has the function of self-calibration. The ultimate goal of the self-calibrated spectrometer is to be the radiation reference of the space optical remote sensor in the visible ~ near infrared band. Other optical remote sensors are calibrated. Finally, the accuracy and volume limitations of the current data acquisition system are analyzed. A design scheme of high precision and miniaturization data acquisition system based on time digital converter (TDC) is presented.
【学位授予单位】:中国科学技术大学
【学位级别】:硕士
【学位授予年份】:2017
【分类号】:TH74;TP274;TP311.52
【参考文献】
相关期刊论文 前10条
1 盛文阳;李健军;夏茂鹏;庞伟伟;高冬阳;郑小兵;;基于参量下转换的3.39μm中红外辐射源定标实验[J];红外与激光工程;2016年10期
2 张森;陶旭;冯志军;吴淦华;薛莉;闫夏超;张蜡宝;贾小氢;王治中;孙俊;董光焰;康琳;吴培亨;;超导单光子探测器暗计数对激光测距距离的影响[J];物理学报;2016年18期
3 董瑶海;;风云四号气象卫星及其应用展望[J];上海航天;2016年02期
4 胡友勃;李健军;夏茂鹏;高冬阳;郑小兵;;光子计数器的线性测量和修正[J];光子学报;2016年06期
5 王玉鹏;胡秀清;王红睿;叶新;方伟;;可在轨溯源的太阳反射波段光学遥感仪器辐射定标基准传递链路[J];光学精密工程;2015年07期
6 陈海东;史学舜;赵坤;刘长明;;基于LabVIEW的单光子探测器量子效率测控软件设计[J];宇航计测技术;2015年03期
7 王敏;何明元;张水平;陈晓颖;邱敏;;通道式可见光近红外卫星遥感器辐射定标方法综述[J];遥感信息;2014年01期
8 吕亮;张寅超;林延东;;纠缠光子法绝对定标光电探测器量子效率的研究[J];光学学报;2012年01期
9 任建伟;麦镇强;万志;李宪圣;李凤有;;星上LED定标光源的可行性研究[J];光学精密工程;2008年03期
10 张祥雪;张立;;单光子计数器的校验方法研究[J];光学技术;2007年04期
相关博士学位论文 前2条
1 赵维宁;高精度可溯源SI在轨绝对光谱辐亮度定标传递链路研究[D];中国科学院研究生院(长春光学精密机械与物理研究所);2016年
2 白云飞;自发参量下转换制备单光子源及其测量与应用研究[D];山西大学;2011年
相关硕士学位论文 前3条
1 王力;基于LabVIEW的高速数据采集系统的软硬件设计[D];南京理工大学;2013年
2 裴任;基于FPGA的高精度符合计数器设计[D];南京邮电大学;2013年
3 卢萍;新型全光纤OCT实验系统的控制及数据采集[D];天津大学;2007年