基于光纤陀螺和加速度计的大坝面板挠度测量研究
发布时间:2018-05-10 18:28
本文选题:面板挠度 + 光纤陀螺 ; 参考:《水力发电》2016年04期
【摘要】:结合光纤陀螺和加速度计测量堆石坝面板挠度的特点,利用卡尔曼滤波融合进行捷联解算,解决了光纤陀螺因长时间测量存在漂移影响测量精度、小车运行时有线性加速度加速度计无法准确测量动态倾角的问题。现场试验表明,多次试验结果的重复性较好,测量系统性能稳定,测点连续,精度较高,验证了该方法的可行性和有效性。为高混凝土面板堆石坝面板挠度变形监测提供了新的思路。
[Abstract]:Combined with the characteristics of fiber-optic gyroscope and accelerometer to measure the deflection of rockfill dam panel, the strapdown solution of fiber-optic gyroscope is solved by using Kalman filter fusion. There is the problem that the linear accelerometer can not accurately measure the dynamic inclination angle when the car is running. The field test shows that the repeated test results are good, the measurement system is stable, the measuring points are continuous, and the accuracy is high. The feasibility and effectiveness of the method are verified. It provides a new idea for deformation monitoring of face slab of high concrete face rockfill dam.
【作者单位】: 三峡大学水利与环境学院;南昌工学院建筑工程学院;华北水利水电大学资源与环境学院;三峡大学土木与建筑学院;
【分类号】:TV641.43
【相似文献】
相关期刊论文 前2条
1 宋万石;;董箐水电站光纤陀螺监测面板挠度新技术及其运行轨道安装[J];贵州水力发电;2009年05期
2 ;[J];;年期
相关硕士学位论文 前1条
1 罗德新;光纤陀螺技术在工程结构监测中的应用研究[D];武汉理工大学;2005年