当前位置:主页 > 科技论文 > 水利工程论文 >

某水电机组异常水力振动分析与处理

发布时间:2018-09-13 09:43
【摘要】:某水电机组在运行时,发现压力脉动、机组振动与噪声较往常明显增大,且随负荷的增加而增大,这将严重威胁机组的安全稳定运行。为此进行了变负荷试验,对变负荷数据进行分析,发现活动导叶过流不均是引起机组振动过大的原因,停机检查发现活动导叶处卡有异物,取出异物后,机组压力脉动与振动过大问题得到解决,为类似问题的处理提供了参考依据。
[Abstract]:When a hydroelectric unit is in operation, it is found that the pressure pulsation, the vibration and noise of the unit are obviously increased than usual, and increase with the increase of load, which will seriously threaten the safe and stable operation of the unit. For this reason, the variable load test was carried out, and the variable load data were analyzed. It was found that the uneven flow of the moving guide vane was the cause of the excessive vibration of the unit. The problems of pressure pulsation and excessive vibration are solved, which provides a reference for the treatment of similar problems.
【作者单位】: 国网新源控股有限公司技术中心;
【分类号】:TV738

【相似文献】

相关期刊论文 前10条

1 ;我国自主研制世界最大水电机组[J];水电厂自动化;2008年02期

2 ;引进水电机组技术研讨会在富春江召开[J];水力发电;1994年11期

3 ;“700MW级巨型水电机组研制”被授予四川省重大科技成果转化示范项目[J];东方电气评论;2013年04期

4 沈磊;采用指标控制法监测水电机组的稳定运行[J];东北电力技术;2000年05期

5 李连贵;水电机组用新型制动器开发成功[J];发电设备;2001年05期

6 周波;改善水电机组运行稳定性[J];电器工业;2004年05期

7 施炳利;小型水电机组取消永磁机出现的问题及解决方法[J];河北水利;2004年08期

8 瞿f,