【摘要】:提出了一种全数字化的B超成像系统解决方案,该系统具有16通道80阵元,采用高集成度的超声波发射与回波接收电路设计,基于FPGA和USB技术实现数字化超声成像.与传统模拟解决方案相比,本设计大大降低了系统的面积与功耗,有较高的分辨率与探测精度,具有更高的医学诊断价值,并且能够在社区医疗、大型赛事等方面得到推广.同时在此方案基础上进行了系统雏形的设计与实现,从系统的角度验证方案的可行性.
[Abstract]:In this paper, a fully digital B ultrasonic imaging system is proposed. The system has 16 channels and 80 array elements. The system is designed with high integration of ultrasonic emission and echo receiving circuit. Digital ultrasonic imaging is realized based on FPGA and USB technology. Compared with the traditional analog solution, this design greatly reduces the area and power consumption of the system, has higher resolution and detection accuracy, and has higher value of medical diagnosis. And it can be popularized in community medical treatment, large-scale competition and so on. At the same time, the system prototype design and implementation are carried out on the basis of this scheme, and the feasibility of the scheme is verified from the point of view of the system.
【作者单位】: 东北大学计算机科学与工程学院;
【基金】:中央高校基本科研业务费项目(N140404001)
【分类号】:TB559;TN791

【参考文献】

相关期刊论文 前1条

1 仝仁;武剑辉;栾强厚;王正发;;基于集成芯片的医用超声前端发射电路设计[J];医疗卫生装备;2012年10期

【共引文献】

相关期刊论文 前1条

1 李大宇;阮宇航;孙东征;张石;;基于FPGA的高集成度便携式B超成像系统[J];北京理工大学学报;2017年07期

【二级参考文献】

相关期刊论文 前9条

1 吴强;;医学超声诊断设备中的若干新技术[J];医疗装备;2011年04期

2 熊世杰;武剑辉;;彩超中的数字多波束形成技术研究[J];医疗卫生装备;2010年08期

3 幸坤涛;刘晓文;;基于8通道高压开关HV20220的B超探头电路设计[J];电子世界;2009年07期

4 林轶翰;陈思平;;医学超声影像技术及展望[J];医疗装备;2006年06期

5 林武平;;基于FPGA的B超收发前端电路设计[J];仪器仪表用户;2006年01期

6 毕素栋;医学超声影像诊断设备的进展[J];医疗卫生装备;2005年04期

7 霍福涛,张秀珍,吴胜勇;超声学进展[J];国外医学(临床放射学分册);2005年02期

8 高上凯;医学超声仪器技术发展的现状和展望[J];中国医疗器械杂志;2002年06期

9 王威琪,汪源源,余建国;诊断用医学超声学的现状[J];声学技术;2002年Z1期



本文编号:1609805

资料下载
论文发表

本文链接:https://www.wllwen.com/kejilunwen/wulilw/1609805.html


Copyright(c)文论论文网All Rights Reserved | 网站地图 |

版权申明:资料由用户2a49c***提供,本站仅收录摘要或目录,作者需要删除请E-mail邮箱bigeng88@qq.com