超高场3.0T MRI不同序列应用于腰骶神经根成像的比较
发布时间:2019-03-26 18:21
【摘要】:目的:比较3.0T MRI FIESTA与IDEAL序列腰骶神经根受压成像的诊断价值。方法:22例腰椎间盘突出患者分别行常规序列、FIESTA序列和IDEAL序列扫描,所有图像均进行后处理重建,对图像的质量和清晰度、受压神经显示清晰度、腰骶神经根与邻近椎体(脑脊液)的对比噪声比4个方面进行评价。结果:神经根-脑脊液CNR值FIESTA序列明显大于IDEAL序列(283.24±117.97 vs 96.28±39.29,P=0.000),图像质量及清晰度评分FIESTA序列大于IDEAL序列(4.66±0.33 vs 4.22±0.68,P=0.028),受压神经显示清晰度IDEAL序列大于FIESTA序列(2.78±0.45 vs 2.19±0.83,P=0.023),差异均有统计学意义。结论:FIESTA序列扫描时间短,观察神经根受压及治疗前后比较,较有优势;IDEAL序列对于受压神经根的定位、神经根受压及损伤程度的成像特点更有优势。
[Abstract]:Objective: to compare the diagnostic value of lumbosacral nerve root compression imaging between 3.0T MRI FIESTA and IDEAL sequence. Methods: 22 patients with lumbar disc herniation were scanned with conventional sequence, FIESTA sequence and IDEAL sequence respectively. All the images were post-processed and reconstructed. The quality and clarity of the images and the clarity of the compressed nerve were observed. The contrast noise ratio between lumbosacral nerve root and adjacent vertebral body (cerebrospinal fluid) was evaluated in four aspects. Results: the CNR value of nerve root and cerebrospinal fluid in FIESTA sequence was significantly higher than that in IDEAL sequence (283.24 卤117.97 vs 96.2839.29, P < 0.000). The image quality and clarity score of FIESTA sequence was higher than that of IDEAL sequence (4.66 卤0.33 vs 4.22 卤0.68, P < 0.028). The IDEAL sequence of compressed nerve showed greater clarity than that of FIESTA sequence (2.78 卤0.45 vs 2.19 卤0.83, P < 0.023), and the difference was statistically significant. Conclusion: the scanning time of FIESTA sequence is short, it has advantage to observe nerve root compression and compare before and after treatment, and IDEAL sequence has advantage in localization of compressed nerve root, compression of nerve root and degree of injury.
【作者单位】: 安徽医科大学空军临床学院;空军总医院磁共振科;河北北方学院研究生部;
【分类号】:R445.2
[Abstract]:Objective: to compare the diagnostic value of lumbosacral nerve root compression imaging between 3.0T MRI FIESTA and IDEAL sequence. Methods: 22 patients with lumbar disc herniation were scanned with conventional sequence, FIESTA sequence and IDEAL sequence respectively. All the images were post-processed and reconstructed. The quality and clarity of the images and the clarity of the compressed nerve were observed. The contrast noise ratio between lumbosacral nerve root and adjacent vertebral body (cerebrospinal fluid) was evaluated in four aspects. Results: the CNR value of nerve root and cerebrospinal fluid in FIESTA sequence was significantly higher than that in IDEAL sequence (283.24 卤117.97 vs 96.2839.29, P < 0.000). The image quality and clarity score of FIESTA sequence was higher than that of IDEAL sequence (4.66 卤0.33 vs 4.22 卤0.68, P < 0.028). The IDEAL sequence of compressed nerve showed greater clarity than that of FIESTA sequence (2.78 卤0.45 vs 2.19 卤0.83, P < 0.023), and the difference was statistically significant. Conclusion: the scanning time of FIESTA sequence is short, it has advantage to observe nerve root compression and compare before and after treatment, and IDEAL sequence has advantage in localization of compressed nerve root, compression of nerve root and degree of injury.
【作者单位】: 安徽医科大学空军临床学院;空军总医院磁共振科;河北北方学院研究生部;
【分类号】:R445.2
【参考文献】
相关期刊论文 前4条
1 夏吉凯;刘新疆;房清敏;张迪;范万峰;王滨;;IDEAL序列在臂丛神经扫描方案中的对比研究[J];磁共振成像;2014年02期
2 惠毅毅;王庆征;李传亭;刘传梅;张红;;3T MR三维稳态进动快速成像序列显示脑池段颅神经及其与周围病变的关系[J];医学影像学杂志;2012年03期
3 蹇朴;曾南林;蹇素;张小明;;磁共振3D-FIESTA序列对L1~L5脊神经解剖的研究[J];中国医学计算机成像杂志;2006年03期
4 张林医;崔现成;许洋;孙永青;;臂丛神经的磁共振成像[J];医疗装备;2013年05期
【共引文献】
相关期刊论文 前10条
1 尤超;陈克敏;柴维敏;;三叉神经痛的MR成像[J];放射学实践;2011年08期
2 赵光明;陈克敏;;三叉神经微血管压迫的争论[J];国外医学(临床放射学分册);2007年01期
3 闫瑞芳;沈桂权;;三叉神经痛的磁共振成像新进展[J];贵州医药;2007年01期
4 汪t,
本文编号:2447809