义齿清洁剂对不同球帽附着体固位力的影响
[Abstract]:Objective to simulate the immersion of three kinds of denture cleaners on two kinds of ball cap attachments in vitro, and to determine the change of retention force by using fatigue testing machine, in order to investigate the effect of different denture cleaners on the retention force of ball cap attachments. To provide guidance for clinical application of denture cleaner. Materials and methods 1. Four positive baskets were selected for ball cap attachment, 8 for O type bad cap, 20 for yellow and 20 for red O type clamping pad. Each group was randomly divided into four groups: control group (water), experimental group (Polaridine, chlorhexidine, 0.5% sodium hypochlorite). The initial retention force of each assembly was measured by fatigue testing machine, and the change of the retention force of the ball cap attachment with time was recorded when the ball cap was dislocated at one time. 2. Under the electrothermal incubator, the retention force of the simulated clinical denture cleaner for one year was recorded, and the retention force of each group of ball cap attachments during January, March, June, September, and one year was recorded. The ball cap attachment was fixed on the fatigue testing machine and the retention force of 1000 times dislocation was measured. The experimental data of each group were statistically analyzed by SPSS19.0 (伪 = 0. 05). The initial retention force of the red O pad is higher than that of the yellow O pad. The retention force of the ball cap attachment increases gradually with the time of the first dislocation, and the highest point of the curve represents the retention force of the ball cap attachment. Then gradually decreased and then disappeared. 2. After being soaked in three kinds of denture cleaners for 12 months, the retention forces of the red and yellow ball cap attachments were significantly different (P0.05), but there was no significant difference in attenuation values among the groups (P0.05). To explore the immersion time when affecting the retention force, it was found that the retention force of the attachment changed significantly after the clinical application of three kinds of denture cleaners (P0.05). After soaking in detergent for one year, the attenuation rate of retention force in each group was found to be the highest in sodium hypochlorite group, which was significantly different from that in other groups (P0.05), and then after 1000 dislocations, the attenuation rate of red O-ring was the highest in sodium hypochlorite group. The attenuation rate of retention force in sodium hypochlorite group is still obvious. 4. 4. By describing the curve of the retention force of the ball cap attachment with the immersion time, it was found that the retention force of the control group had no obvious attenuation, but the retention force in the experimental group gradually decreased with the increase of the immersion time. Conclusion 1. The initial retention force of the ball cap attachment is low, the selection of the type and quantity of the O-pad should be paid attention to when selecting the ball cap attachment, and the denture cleaner has an effect on the retention force of the ball cap attachment with different colors. In sodium hypochlorite solution, the retention force of the ball cap attachment is more attenuated than that of the other groups, so it is not recommended that sodium hypochlorite solution be used as a cleaning agent to treat the ball cap attachment. 2. The retention force decreased after one month after immersion denture cleaner, so short-term immersion has an effect on the retention force of ball cap attachment. After repeated dislocation for 1000 times, the retention force of the three groups was significantly lower than that of the control group, so the denture cleaner had an effect on the final retention force.
【学位授予单位】:郑州大学
【学位级别】:硕士
【学位授予年份】:2017
【分类号】:R783.6
【相似文献】
相关期刊论文 前10条
1 郭进新,袁文钧,程祥荣;加酶义齿清洁剂对口腔厌氧菌的杀菌效果实验[J];武汉大学学报(医学版);2001年03期
2 曹全录;王振忠;刘玉英;;牙刷和义齿清洁剂的研制及应用[J];现代口腔医学杂志;1989年04期
3 邓益辉,李清,张淑琴,曹海星;自制义齿清洁剂的抑菌及临床疗效观察[J];临床口腔医学杂志;1997年03期
4 许力强,罗云纲,金辰,陈红玉;义齿的清洁及义齿清洁剂[J];白求恩医科大学学报;1999年05期
5 袁文钧,程祥荣,张国晴,樊帆,徐东选,艾军,袁军;高效酶型义齿清洁剂的研制[J];口腔医学纵横;2001年01期
6 邓旭亮 ,胡晓阳 ,李国珍 ,黄汝丽;义齿清洁剂对树脂基托颜色的影响[J];现代口腔医学杂志;2003年01期
7 黄元瑾,刘曙光,段培佳;三种义齿清洁剂的临床疗效评价[J];广东医学;2004年05期
8 张燕萍;吴凤鸣;;5种义齿清洁剂对白色念珠菌生物膜清洁效果的比较[J];口腔医学研究;2011年05期
9 宋东哲;李波儿;罗云;胡沛;谢秉理;毕瑞野;;义齿清洁剂临床使用情况调查分析[J];西部医学;2011年09期
10 袁文钧,张国晴;义齿清洁剂[J];口腔材料器械杂志;1998年04期
相关会议论文 前9条
1 王延民;;自制“按扣式”附着体的临床应用[A];中华口腔医学会第三次全国口腔修复学术会议论文集[C];1997年
2 冯海兰;;附着体临床应用的10年回顾[A];中华口腔医学会第二次全国会员代表大会暨第七次全国口腔医学学术会议论文汇编[C];2001年
3 于书娟;李笑梅;汪大林;周中华;;在前端种植体固定桥和后端附着体义齿修复上颌无牙颌修复中:不同附着体类型的应力分析[A];2004年上海市口腔医学学术年会论文汇编[C];2004年
4 骆小平;欧阳官;贾安琦;郭天文;;根上附着体桩柱形态设计对牙本质应力分布的影响[A];中华口腔医学会第三次全国口腔修复学术会议论文集[C];1997年
5 石韶青;;附着体式可摘局部义齿的临床应用[A];全国第六届口腔修复工艺学学术会议论文汇编[C];2007年
6 王贻宁;Per-Olof Glantz;Krister Ninler;;不同附着体对种植体支持式覆盖义齿影响的应力分析——Ⅰ.杆式附着体与球形附着体[A];中华口腔医学会成立大会暨第六次全国口腔医学学术会议论文汇编[C];1996年
7 刘敏;王仁飞;;烤瓷和附着体联合修复重度磨耗的修复效果[A];浙江省口腔医学会第二届会员代表大会暨浙江省第二十三届口腔医学学术会议论文汇编[C];2004年
8 王本性;张洁;王民庆;周庆立;葛彪;夏小仙;;教育导热硫化硅橡胶与高溶合金粘结的研究[A];中华口腔医学会成立大会暨第六次全国口腔医学学术会议论文汇编[C];1996年
9 任煜光;黄桂钦;周耀皓;;VKS—SG附着体用于两侧游离端缺牙可摘义齿修复体会[A];中华口腔医学会第三次全国口腔修复学术会议论文集[C];1997年
相关博士学位论文 前1条
1 贾安琦;附着体应用于游离端可摘部分义齿的三维有限元应力分析比较[D];第四军医大学;1993年
相关硕士学位论文 前10条
1 张燕萍;义齿清洁剂清洁效果及对义齿基托性能影响的研究[D];南京医科大学;2011年
2 胡航;义齿清洁剂对着色拜耳牙洁美效果的研究[D];武汉大学;2005年
3 赵路遥;氮化钛薄膜改良的种植覆盖义齿球帽附着体耐磨损的研究[D];郑州大学;2016年
4 刘波;口腔根帽、球帽附着体的开发研制及临床应用研究[D];天津医科大学;2003年
5 赵锐;口腔栓体栓道附着体的开发研制及临床应用研究[D];天津医科大学;2004年
6 李磊;不同条件的孤立和非孤立基牙使用不同类型附着体修复的临床体会[D];大连医科大学;2012年
7 于书娟;种植体和附着体修复上颌无牙颌的有限元分析[D];第二军医大学;2005年
8 闫通通;纳米载银无机抗菌剂与义齿清洁剂对室温固化型PMMA材料抗菌性能及力学性能的影响[D];吉林大学;2014年
9 段亮伟;下颌单侧游离端缺失球帽附着体修复的三维有限元分析[D];吉林大学;2012年
10 黄韦;应用不同类型附着体的下颌种植覆盖义齿的系统评价[D];四川大学;2006年
,本文编号:2395953
本文链接:https://www.wllwen.com/yixuelunwen/kouq/2395953.html