大连市2009-2012年医院消毒效果监测
发布时间:2018-04-03 13:33
本文选题:医院 切入点:消毒与灭菌 出处:《中国消毒学杂志》2014年01期
【摘要】:目的了解大连市各级医院消毒与灭菌质量,为控制医院感染提供依据。方法采用现场抽样检测方法,对医院不同对象的消毒与灭菌效果进行检测。结果 2009-2012年连续4年共采样2 501份,平均总合格率为86.17%。不同监测对象中,使用中消毒剂、灭菌物品和压力蒸汽灭菌器灭菌效果合格率均为100.00%,物体表面、医务人员手和室内空气合格率分别为90.03%、78.50%和76.76%。结论各级医院消毒与灭菌质量合格率总体不高,医院物体表面、医务人员手和室内空气合格率较低,消毒与灭菌质量还有待提高。
[Abstract]:Objective to understand the quality of disinfection and sterilization in hospitals at all levels in Dalian, and to provide evidence for the control of nosocomial infection.Methods the disinfection and sterilization effects of different objects in hospital were detected by field sampling method.Results from 2009 to 2012, 2 501 samples were collected for 4 consecutive years, and the average qualified rate was 86.17.The eligible rates of disinfectants in use, sterilizing articles and pressure steam sterilizers were 100.00. the qualified rates of object surfaces, hands and indoor air of medical workers were 90.03% and 76.76%, respectively.Conclusion the qualified rate of disinfection and sterilization in hospitals at all levels is not high on the whole, the qualified rate of hospital object surface, medical staff hand and indoor air is low, and the quality of disinfection and sterilization needs to be improved.
【作者单位】: 辽宁省大连市疾病预防控制中心;
【分类号】:R187
【共引文献】
相关期刊论文 前1条
1 赵常智;安静;董雪;;沈阳市2006年~2008年医疗机构消毒效果监测分析[J];中国卫生检验杂志;2009年12期
【二级参考文献】
相关期刊论文 前1条
1 吴建中,吴国强,张缪伟,陈阳,邵健;医院消毒隔离单项指标监测结果分析[J];中国卫生检验杂志;2005年08期