【摘要】:目的了解医疗机构消毒质量状况,为加强医院消毒管理和防控医院感染提供依据。方法通过资料调查和采样检测方法,对河南省医疗机构消毒质量进行调查和分析。结果连续3年共调查河南省医疗机构403所次,共采集不同消毒对象8 959份,消毒质量平均合格率为91.54%。在不同监测对象中,压力蒸汽灭菌器灭菌效果合格率为100%,室内空气消毒合格率仅69.74%,处于最低水平,医院污水处理合格率为88.46%;其余消毒对象合格率均达到90%以上。结论河南省医疗机构消毒质量总体较好,但薄弱环节突出,消毒管理工作仍应加强。
[Abstract]:Objective to understand the disinfection quality of medical institutions and provide evidence for strengthening hospital disinfection management and preventing and controlling nosocomial infection. Methods the disinfection quality of medical institutions in Henan Province was investigated and analyzed by means of data investigation and sampling. Results A total of 403 medical institutions in Henan Province were investigated for 3 consecutive years. 8,959 different disinfection objects were collected, and the average qualified rate of disinfection quality was 91.54. Among the different monitoring objects, the qualified rate of sterilizing effect of pressure steam sterilizer was 100 and the qualified rate of indoor air disinfection was only 69.74, which was at the lowest level, the qualified rate of hospital sewage treatment was 88.46, and the qualified rate of other disinfection objects was above 90%. Conclusion the disinfection quality of medical institutions in Henan Province is good on the whole, but the weak links are prominent, and the disinfection management should be strengthened.
【作者单位】: 河南省疾病预防控制中心;河南省人民医院;
【分类号】:R187
[Abstract]:Objective to understand the disinfection quality of medical institutions and provide evidence for strengthening hospital disinfection management and preventing and controlling nosocomial infection. Methods the disinfection quality of medical institutions in Henan Province was investigated and analyzed by means of data investigation and sampling. Results A total of 403 medical institutions in Henan Province were investigated for 3 consecutive years. 8,959 different disinfection objects were collected, and the average qualified rate of disinfection quality was 91.54. Among the different monitoring objects, the qualified rate of sterilizing effect of pressure steam sterilizer was 100 and the qualified rate of indoor air disinfection was only 69.74, which was at the lowest level, the qualified rate of hospital sewage treatment was 88.46, and the qualified rate of other disinfection objects was above 90%. Conclusion the disinfection quality of medical institutions in Henan Province is good on the whole, but the weak links are prominent, and the disinfection management should be strengthened.
【作者单位】: 河南省疾病预防控制中心;河南省人民医院;
【分类号】:R187
【参考文献】
相关期刊论文 前4条
1 白月莲;于中华;庞尔泽;;2008至2010年某市医疗机构消毒质量监测分析[J];中国医药指南;2011年31期
2 银燕;贾兴真;张聿为;;辽宁省医疗机构消毒效果监测[J];中国消毒学杂志;2008年01期
3 张玉勤;李书建;王z,
本文编号:2124228
本文链接:https://www.wllwen.com/yixuelunwen/liuxingb/2124228.html