当前位置:主页 > 医学论文 > 生物医学论文 >

一种新的电外科仪器输出参数测量系统

发布时间:2019-06-07 11:11
【摘要】:对电外科仪器输出的高压和大电流参数进行准确检测是研制反馈式电外科仪器的基础。为此,本文研制基于PC机的输出参数测量系统,对电外科仪器输出的高压和大电流信号进行隔离感应、放大、滤波、差分信号变单端信号、有效值转换,最后通过DAQ采集卡进行模数转换,数据送入PC机中使用Labview软件进行过采样、显示和存储等处理。实验结果表明,该系统能够对电外科仪器的输出参数进行稳定测量,结果准确。因此,该系统的研制是成功的,在此基础上开发嵌入式的输出参数测量系统,能够为智能式的电外科仪器开发提供准确的反馈信息。
[Abstract]:The accurate detection of high voltage and high current parameters of electric surgical instruments is the basis of the development of feedback electric surgical instruments. For this reason, an output parameter measurement system based on PC is developed in this paper. The high voltage and high current signals outputted by electric surgical instruments are isolated and induced, amplified, filtered, differential signals become single-ended signals, and the effective values are converted. Finally, the analog-to-digital conversion is carried out through DAQ acquisition card, and the data is sent to PC for over-sampling, display and storage by Labview software. The experimental results show that the system can measure the output parameters of electric surgical instruments stably, and the results are accurate. Therefore, the development of the system is successful, on the basis of which the embedded output parameter measurement system can provide accurate feedback information for the development of intelligent electrical surgical instruments.
【作者单位】: 上海理工大学医疗器械与食品学院;
【基金】:上海市科委资助项目(10441900900) 上海市教委科研创新项目资助项目(12YZ102) 上海市优秀青年教师科研专项基金(slg10020)
【分类号】:R318.6

【参考文献】

相关期刊论文 前1条

1 李刚;张丽君;林凌;何峰;;基于过采样技术的生物电信号检测[J];电子学报;2008年07期

【共引文献】

相关期刊论文 前10条

1 邹宇杰;胡永建;;基于过零点检测的高分辨率DAC静态测试方法研究[J];电子技术;2011年09期

2 李刚;周梅;何峰;林凌;;基于数字锁相相关计算结构的优化算法[J];电子与信息学报;2012年03期

3 李刚;赵U,

本文编号:2494750


资料下载
论文发表

本文链接:https://www.wllwen.com/yixuelunwen/swyx/2494750.html


Copyright(c)文论论文网All Rights Reserved | 网站地图 |

版权申明:资料由用户e93e0***提供,本站仅收录摘要或目录,作者需要删除请E-mail邮箱bigeng88@qq.com