高分辨肛管直肠测压与水灌注肛管直肠测压所得正常参考值的比较研究
发布时间:2019-03-08 08:43
【摘要】:目的比较高分辨肛管直肠测压与传统水灌注肛管直肠测压正常参考值的差异。方法招募22例正常志愿者先后完成高分辨肛管直肠测压和水灌注肛管直肠测压,比较两种方法所得肛管静息压、收缩压、肛管功能长度及直肠黏膜敏感性的差异。结果水灌注肛管直肠测压所得到的肛管静息压、收缩压及功能长度的正常参考值均低于高分辨测压所得到的正常参考值(P0.05);水灌注肛管直肠测压正常参考值与手动分析的高分辨肛管直肠测压的正常参考值比较无明显差异。结论高分辨肛管直肠测压所测得肛管静息压、收缩压及肛管功能长度均大于水灌注肛管直肠测压所测得的正常参考值
[Abstract]:Objective to compare the difference of normal reference values between high resolution anorectal manometry and conventional water perfusion anorectal manometry. Methods 22 normal volunteers were recruited to complete high-resolution anorectal manometry and water perfusion anorectal manometry. The differences of anal resting pressure, systolic blood pressure, anal function length and rectal mucosal sensitivity between the two methods were compared. Results the normal reference values of anal resting pressure, systolic blood pressure and functional length obtained by water perfusion anorectal manometry were lower than those obtained by high resolution manometry (P0.05). There was no significant difference between the normal reference value of water perfusion anorectal manometry and the normal reference value of high resolution anorectal manometry analyzed by hand. Conclusion the anal resting pressure, systolic blood pressure and anal function length measured by high resolution anorectal manometry are larger than the normal reference values measured by water perfusion anorectal manometry.
【作者单位】: 中山大学附属第六医院盆底中心;
【分类号】:R574
本文编号:2436634
[Abstract]:Objective to compare the difference of normal reference values between high resolution anorectal manometry and conventional water perfusion anorectal manometry. Methods 22 normal volunteers were recruited to complete high-resolution anorectal manometry and water perfusion anorectal manometry. The differences of anal resting pressure, systolic blood pressure, anal function length and rectal mucosal sensitivity between the two methods were compared. Results the normal reference values of anal resting pressure, systolic blood pressure and functional length obtained by water perfusion anorectal manometry were lower than those obtained by high resolution manometry (P0.05). There was no significant difference between the normal reference value of water perfusion anorectal manometry and the normal reference value of high resolution anorectal manometry analyzed by hand. Conclusion the anal resting pressure, systolic blood pressure and anal function length measured by high resolution anorectal manometry are larger than the normal reference values measured by water perfusion anorectal manometry.
【作者单位】: 中山大学附属第六医院盆底中心;
【分类号】:R574
【相似文献】
相关期刊论文 前10条
1 胡俊川,周兵,王前清;肛管直肠损伤的诊断及治疗[J];中国综合临床;2004年09期
2 徐其佐,喻德洪;肛管直肠损伤的诊治现状[J];创伤外科杂志;2001年03期
3 徐林富;肛管直肠损伤17例诊治体会[J];浙江临床医学;2001年07期
4 孟荣贵,郝立强;肛管直肠损伤的诊断及治疗[J];腹部外科;2002年02期
5 陈德谊;盆腔放疗后的肛管直肠损伤[J];国外医学.外科学分册;2002年02期
6 刘勤远;肛管直肠损伤[J];人民军医;1994年09期
7 刘喜武,郑培臣;肛管直肠异物诊治体会[J];航空航天医药;1998年03期
8 黄小靖,刘永华;肛管直肠损伤16例治疗体会[J];福建医药杂志;1999年01期
9 蒋波,师新荣,李海;肛管、直肠损伤21例诊治[J];宁夏医学院学报;2005年02期
10 陈莉;肛管超声对肛管直肠疾病的诊断价值[J];中国超声医学杂志;1994年01期
,本文编号:2436634
本文链接:https://www.wllwen.com/yixuelunwen/xiaohjib/2436634.html
最近更新
教材专著