饮用水臭氧水机评价方法初探
本文选题:饮用水 + 臭氧水机 ; 参考:《环境与健康杂志》2017年02期
【摘要】:目的探讨饮用水臭氧水机的评价方法,为市场准入提供安全有效的检测评价方案。方法在臭氧水机的额定产水量内,自来水以1.0 L/min流速流经该净水器,通过中和剂鉴定、总体性能、饮用水消毒效果、臭氧水定量杀菌等试验对饮用水臭氧水机的安全及应用效果进行评价。结果含0.2%硫代硫酸钠、0.2%吐温-80的0.03 mol/L PBS溶液的中和剂和中和产物对大肠杆菌及培养基无不良影响。总体性能试验、饮用水消毒效果试验符合《生活饮用水消毒剂和消毒设备卫生安全评价规范》(试行)和GB 5749—2006《生活饮用水卫生标准》的要求;当作用时间达到30 min时,该臭氧水机产生的臭氧水对染菌载体上的大肠杆菌、金黄色葡萄球菌、铜绿假单胞菌杀灭的对数值均大于3,符合《消毒技术规范》(2002)的要求。结论通过中和剂鉴定、总体性能、饮用水消毒效果、臭氧水定量杀菌等指标可对臭氧水机的使用安全性能及消毒应用效果等做出全面的评价。
[Abstract]:Objective to explore the evaluation method of drinking water ozone water machine and to provide a safe and effective test and evaluation scheme for market access.Methods within the rated water production of ozone water machine, tap water passed through the water purifier at a flow rate of 1.0 L/min. The overall performance and disinfection effect of drinking water were evaluated by neutralizer.The safety and application effect of ozone water machine were evaluated by ozone water quantitative sterilization test.Results the neutralizer and neutralization product of 0.03 mol/L PBS solution containing 0.2% sodium thiosulfate (0.2% Tween-80) had no adverse effects on Escherichia coli and culture medium.The overall performance test and the drinking water disinfection effect test meet the requirements of the Standard for Sanitary Safety Evaluation of domestic drinking Water disinfectants and Disinfection Equipments (for trial implementation) and GB5749-2006 for drinking Water Sanitation Standards. When the working time reaches 30 min,The ozone water produced by the ozone water machine can kill Escherichia coli, Staphylococcus aureus and Pseudomonas aeruginosa on the carrier of bacteria more than 3, which meets the requirements of Technical Specification for Disinfection (2002).Conclusion through the identification of neutralizer, overall performance, disinfection effect of drinking water and quantitative sterilization of ozone water, the safety performance and disinfection application effect of ozone water machine can be comprehensively evaluated.
【作者单位】: 中国疾病预防控制中心环境与健康相关产品安全所;
【分类号】:R123.6
【相似文献】
相关期刊论文 前10条
1 薄玉霞,王歆宇,王万海,刘吉起,王立争;水中臭氧杀菌效果的试验观察[J];现代预防医学;2004年03期
2 代欣欣;李汴生;;水中臭氧溶解特性的研究[J];食品科技;2008年08期
3 刘晓杰,庄华君,王艳秋,黄新宇,孙利群;臭氧水消毒效果试验观察[J];中国卫生工程学;2004年02期
4 周鹏;张静;李旺;杨忆新;杨颖;崔鹏;;天然水体中臭氧链式分解模拟研究[J];黑龙江大学自然科学学报;2013年05期
5 张征;;饮用水臭氧消毒效果的影响因素[J];环境与健康杂志;2008年05期
6 Kristin Aunan;Terje Koren Berntsen;Hans Martin Seip;闵庆文;;中国的地面臭氧及其对农作物产量的可能影响[J];AMBIO-人类环境杂志;2000年06期
7 林英伟;;臭氧洗衣技术探讨[J];广州环境科学;2000年04期
8 宋钰,蔡士林,张卫强;水中臭氧的快速测定[J];卫生研究;2000年03期
9 马运明;王华然;王福玉;李迎凯;尹静;;臭氧灭活水中f_2噬菌体的效果研究[J];环境与健康杂志;2009年12期
10 杨胜凡;廖振方;;一种新型节能臭氧发生器[J];广州环境科学;2006年04期
相关重要报纸文章 前1条
1 本报记者 汤璇;臭氧处理医疗废水值得推广[N];广东建设报;2007年
相关硕士学位论文 前1条
1 蔡璇;臭氧/游离氯及其组合工艺对饮用水中病毒灭活影响因素研究[D];复旦大学;2012年
,本文编号:1763817
本文链接:https://www.wllwen.com/yixuelunwen/yufangyixuelunwen/1763817.html