人体胸壁厚度对肺部计数器探测效率的影响研究
发布时间:2018-06-20 02:00
本文选题:肺部计数器 + 体素模型 ; 参考:《核电子学与探测技术》2015年12期
【摘要】:人体胸壁厚度是影响肺部放射性核素测量准确性的重要参数。基于数字体素模型和MC法,计算得到了不同胸壁厚度条件下,肺部计数器对241Am出射光子的探测效率,进而研究了3组不同人群胸壁厚度差异造成的探测效率偏差。结果显示:胸壁厚度对241Am测量结果的影响严重,出射光子能量越低胸壁厚度影响越大;相较平均胸壁厚度时的探测效率,对于17.6keV光子,偏差可达308.0%,对于59.5keV光子,偏差可达50.0%。
[Abstract]:The thickness of human chest wall is an important parameter that affects the accuracy of radionuclide measurement. Based on the digital voxel model and MC method, the detection efficiency of 241Am emission photon by lung counter under different chest wall thickness conditions was calculated, and the detection efficiency deviation caused by the difference of chest wall thickness in three groups of people was studied. The results show that the thickness of chest wall has a serious effect on the measurement results of 241Am, the lower the energy of emerging photon, the greater the thickness of chest wall, and the detection efficiency of the average thickness of chest wall is 308.0 for 17.6 KeV photons and 50.0 for 59.5 Kev photons.
【作者单位】: 西北核技术研究所;
【分类号】:R14
【相似文献】
相关期刊论文 前6条
1 成智威;毛永;马如维;陈宝维;韩月琴;田自宁;巨凌军;董正鹏;;超铀元素肺部计数器的效率刻度技术[J];辐射防护;2009年06期
2 成智威;申茂泉;张洋;;小波分析方法在肺部计数器解谱中的应用[J];中国辐射卫生;2012年03期
3 张斌全;马吉增;程建平;杨端节;刘立业;;使用人体躯干物理模型的CT模型和蒙特卡罗方法校准肺部计数器[J];辐射防护;2006年02期
4 成智威;贾明雁;程建平;申茂泉;黎先利;田自宁;巨凌军;;肺部计数器测量肺内氡子体的可行性研究[J];中国辐射卫生;2011年01期
5 刘立业;Didier Franck;Loicde Carlan;马吉增;张斌全;;基于Livermore模型CT图片构建人体躯干数字体模及其在肺部计数器虚拟刻度中的应用[J];辐射防护;2007年05期
6 ;[J];;年期
相关会议论文 前1条
1 成智威;田自宁;巨凌军;;超铀元素肺部计数器的效率刻度[A];全国个人剂量监测研讨会论文汇编[C];2008年
相关博士学位论文 前1条
1 成智威;基于肺部计数器的内照射监测和剂量评价技术研究[D];清华大学;2014年
相关硕士学位论文 前1条
1 田言杰;峰谷比法测量等效胸壁厚度技术研究[D];哈尔滨工程大学;2013年
,本文编号:2042401