超重患者行CTPA检查时80kV与120kV对照研究
发布时间:2018-10-09 09:40
【摘要】:目的比较80 kV与120 kV条件下超重及肥胖患者的CTPA图像质量及辐射剂量,实现图像质量及辐射剂量的个人优化。方法纳入临床疑似肺栓塞并行CTPA检查的超重(25≤BMI28 kg/m2)及肥胖患者(BMI≥28 kg/m2)患者,随机分配到80 kV与120 kV组。测量肺动脉主干、右肺上叶动脉及右肺下叶后基底段动脉CT值,计算并比较肺动脉平均CT值、信噪比(SNR)、对比信噪比(CNR)及辐射剂量。结果高、低管电压组相同BMI亚组肺动脉平均CT值及辐射剂量相比差异有统计学意义(P0.05),SNR、CNR相比差异无显著性(P0.05);主观图像质量及对肺栓塞显示率相比差异无显著性(P0.05);同一管电压组不同BMI亚组肺动脉平均CT值、CNR及辐射剂量相比差异均有统计学意义(P0.05);而主观图像质量评分差异无显著性(P=0.162~0.301)。结论80 kV管电压条件下的CTPA主观图像质量及诊断可信度与120 kV相比差异无显著性,且受检者所受辐射剂量小,可用于临床疑似肺栓塞的超重及肥胖患者的CTPA检查。
[Abstract]:Objective to compare the CTPA image quality and radiation dose of overweight and obese patients at 80 kV and 120 kV, and to optimize the image quality and radiation dose. Methods overweight (25 鈮,
本文编号:2258871
[Abstract]:Objective to compare the CTPA image quality and radiation dose of overweight and obese patients at 80 kV and 120 kV, and to optimize the image quality and radiation dose. Methods overweight (25 鈮,
本文编号:2258871
本文链接:https://www.wllwen.com/yixuelunwen/yundongyixue/2258871.html