绿色建筑新国标体系下的眩光分析标准化研究
发布时间:2018-09-06 10:34
【摘要】:不舒适眩光度是分析室内自然采光的重要评价指标之一。在《绿色建筑评价标准》(GB/T 50378—2014)中也对自然采光舒适度,要求以模拟手段分析眩光量化指标及改善情况,但并未明确模拟分析的方法和评价准则。利用Radiance光环境分析软件模拟分析的方法,选取一个典型办公室案例,分析了不同朝向和不同天空模型对于不舒适眩光指数(DGI)的影响,建议了绿色建筑新国标体系下的眩光分析方法和评价准则,为《绿色建筑评价标准》在不舒适眩光度下的计算、判定以及改善措施提供方法。
[Abstract]:The degree of uncomfortable glare is one of the important evaluation indexes for the analysis of indoor natural lighting. In GB/T 50378-2014, the natural daylighting comfort is also required to be analyzed by means of simulation, but the methods and evaluation criteria of simulation analysis are not clear. A typical office case was selected to analyze the influence of different orientation and sky model on the uncomfortable glare index (DGI) by using the method of simulation and analysis of Radiance optical environment analysis software. The glare analysis method and evaluation criterion under the new national standard system of green building are suggested, which provides a method for calculating, judging and improving the glare degree of the Green Building Evaluation Standard under the uncomfortable glare degree.
【作者单位】: 上海市建筑科学研究院;
【基金】:国家科技支撑计划课题“性能目标导向的绿色建筑设计优化技术研究”(2012BAJ09B03)
【分类号】:TU201.5;TU113
本文编号:2226098
[Abstract]:The degree of uncomfortable glare is one of the important evaluation indexes for the analysis of indoor natural lighting. In GB/T 50378-2014, the natural daylighting comfort is also required to be analyzed by means of simulation, but the methods and evaluation criteria of simulation analysis are not clear. A typical office case was selected to analyze the influence of different orientation and sky model on the uncomfortable glare index (DGI) by using the method of simulation and analysis of Radiance optical environment analysis software. The glare analysis method and evaluation criterion under the new national standard system of green building are suggested, which provides a method for calculating, judging and improving the glare degree of the Green Building Evaluation Standard under the uncomfortable glare degree.
【作者单位】: 上海市建筑科学研究院;
【基金】:国家科技支撑计划课题“性能目标导向的绿色建筑设计优化技术研究”(2012BAJ09B03)
【分类号】:TU201.5;TU113
【参考文献】
相关期刊论文 前1条
1 李峥嵘;陆瑞阳;赵群;;基于昼光眩光特性的办公建筑遮阳使用需求分析[J];建筑热能通风空调;2014年04期
【相似文献】
相关期刊论文 前6条
1 杨公侠;杨旭东;;不舒适眩光与不舒适眩光评价[J];照明工程学报;2006年02期
2 谢浩;建筑照明设计中不舒适眩光的限制[J];天津城市建设学院学报;1996年Z1期
3 杨公侠;杨旭东;;不舒适眩光与不舒适眩光评价(续上期)[J];照明工程学报;2006年03期
4 俞丽华,沈迎九;CIE眩光指数(CGI)的应用研究[J];照明工程学报;1993年01期
5 唐斌;CIE最新出版物[J];照明工程学报;1995年02期
6 ;[J];;年期
相关重要报纸文章 前2条
1 记者 彭德倩;复旦研制光污染检测器 成功应用于大飞机研发[N];解放日报;2014年
2 中国人民解放军工程大学 崔元日;住宅色彩及照明设计漫淡(下)[N];消费日报;2003年
,本文编号:2226098
本文链接:https://www.wllwen.com/jingjilunwen/jianzhujingjilunwen/2226098.html